Power density of cellular tower against distance, direction and height : a case study

Other Title(s)

كثافة الطاقة الكهرومغناطيسية لبرج الهاتف المحمول مع اختلاف المسافة الاتجاه و الارتفاع : دراسة حالة

Joint Authors

Awad, Abd al-Hamid
Habib Allah, Turki Muhammad

Source

Journal of King Abdul Aziz University : Meteorology, Environment and Arid land Agriculture Sciences

Issue

Vol. 25, Issue 2 (31 Dec. 2014), pp.51-65, 15 p.

Publisher

King Abdulaziz University Scientific Publishing Center

Publication Date

2014-12-31

Country of Publication

Saudi Arabia

No. of Pages

15

Main Subjects

Earth Sciences, Water and Environment
Telecommunications Engineering

Topics

Abstract AR

يعتبر الإشعاع الكهرومغناطيسي الناتج من أبراج الهاتف المحمول أحد أنواع التلوث البيئي و الذي يشكل خطر صحيا، و هو مثير للقلق في أنحاء العالم نظر لتأثيراته غير المرغوب فيها على صحة الإنسان و النبات و الحيوان، و تهدف هذه الدراسة إلى قياس مستويات كثافة الطاقة، الناتجة من برج المحمول مقابل المسافات المختلفة من 10 متر إلى 160 متر عند الاتجاهات الأربعة (الشمال و الجنوب و الشرق و الغرب) و على ارتفاعات 1.5 متر إلى 11 متر من على سطح الأرض.

تم استخدام جهاز TES-593 لقياس كثافة الطاقة و منها تم حساب معامل الامتصاص النوعي و مقارنة كثافة الطاقة و معامل الامتصاص النوعي بالمعايير العالمية.

تخطت كثافة الطاقة معايير بعض الدول ( 0.1) و لكنها أقل من المعايير المسموح بها من قبل المنظمات mW /m2 و الهيئات العالمية التنظمية، و كان معامل الامتصاص النوعي أقل من أن وصل إلى الحدود التي تبدأ عندها ٕ المعايير العالمية (2 واط / كجم)، و التأثيرات البيولوجية، سجلت كثافة الطاقة مستويات مرتفعة عند ارتفاع 11 متر على نفس خط البرج في اتجاه الهوائي، بينما انخفضت بنسبة تتراوح 90 ٪ على ارتفاعات أقل (5-8 متر) داخل المبنى و في نفس اتجاه الهوائي حيث إن العوائق و عدم تجانس البيئة أدى إلى اختلاف نمط توزيع كثافة الطاقة الكهرومغناطيسية.

سجلت أعلى مستويات في اتجاه هوائي المحمول في اتجاهي الشرق و الجنوب، و الأقل عند اتجاه الشمال، تم رصد أعلى مستويات لكثافة الطاقة عند 60-40 متر من البرج، أما في المناطق المفتوحة فكانت عند مسافة 160 متر.

و من ثم فإن قياس المسافة من البرج ليست بالوسيلة التي يمكن الاعتماد عليها لاعتبار المكان آمن أو غير آمن ما لم يتم تحديد الاتجاه و الارتفاع كذلك.

Abstract EN

-The present study aims to evaluate the power density levels emitted from a cellular phone tower at different horizontal distances and heights, in Al-Madinah Al Munawwarah, Saudi Arabia.

A portable meter TES 593 was used to measure the power density levels.

Specific absorption rate was calculated from the measured levels.

The maximum average power density levels ranged between 0.234 mW/m2 and 4.912 mW/m2.

The highest levels were found within 40-50 m in south and north, and 160 m in west and east directions.

The exposure levels were below the international commission on non-ionizing radiation protection (ICNIRP) limit and above the limit values recommended by some countries ( ≤ 1 mW/m2).

The maximum power density ~ 24.3 mW/m2 was found at 11 m height, and 60 m distance from the tower.

The levels reduced by ~ 58.76 % and 99% at 8 m height, 40 m and 60 m distances from the tower, respectively.

Specific absorption rates (SARs) were below the international limit value (2 W/kg).

The highest SAR value constituted 0.4% over the ICNIRP limit value, for 1800 MHz.

The power density levels significantly varied with distance, direction, and height; these factors should be taken into consideration for determining the safety of a place.

American Psychological Association (APA)

Awad, Abd al-Hamid& Habib Allah, Turki Muhammad. 2014. Power density of cellular tower against distance, direction and height : a case study. Journal of King Abdul Aziz University : Meteorology, Environment and Arid land Agriculture Sciences،Vol. 25, no. 2, pp.51-65.
https://search.emarefa.net/detail/BIM-610909

Modern Language Association (MLA)

Awad, Abd al-Hamid& Habib Allah, Turki Muhammad. Power density of cellular tower against distance, direction and height : a case study. Journal of King Abdul Aziz University : Meteorology, Environment and Arid land Agriculture Sciences Vol. 25, no. 2 (2014), pp.51-65.
https://search.emarefa.net/detail/BIM-610909

American Medical Association (AMA)

Awad, Abd al-Hamid& Habib Allah, Turki Muhammad. Power density of cellular tower against distance, direction and height : a case study. Journal of King Abdul Aziz University : Meteorology, Environment and Arid land Agriculture Sciences. 2014. Vol. 25, no. 2, pp.51-65.
https://search.emarefa.net/detail/BIM-610909

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 60-63

Record ID

BIM-610909