A novel method for intraoperative reduction of the mobile meniscal bearing in the oxford unicompartmental knee replacement

Joint Authors

Thompson, Simon M.
Wilson, Daniel G. G.
Patel, Nimesh
Bradley, Neil W.

Source

Journal of Orthopaedics and Trauma

Issue

Vol. 5, Issue 2015 (31 Dec. 2015), pp.1-2, 2 p.

Publisher

Ashdin Publishing Corporation

Publication Date

2015-12-31

Country of Publication

Egypt

No. of Pages

2

Main Subjects

Medicine

Topics

Abstract EN

Insertion of the bearing can be challenging due to patient body habitus or limited exposure when using a minimally invasive technique.

We describe a novel way of inserting the bearing not previously described in the literature.

The bearing is positioned on the femoral component in full flexion.

Then, with a gentle extension of the knee, the bearing snaps into position and is seated correctly on a consistent basis.

American Psychological Association (APA)

Thompson, Simon M.& Wilson, Daniel G. G.& Patel, Nimesh& Bradley, Neil W.. 2015. A novel method for intraoperative reduction of the mobile meniscal bearing in the oxford unicompartmental knee replacement. Journal of Orthopaedics and Trauma،Vol. 5, no. 2015, pp.1-2.
https://search.emarefa.net/detail/BIM-655352

Modern Language Association (MLA)

Thompson, Simon M.…[et al.]. A novel method for intraoperative reduction of the mobile meniscal bearing in the oxford unicompartmental knee replacement. Journal of Orthopaedics and Trauma Vol. 5 (2015), pp.1-2.
https://search.emarefa.net/detail/BIM-655352

American Medical Association (AMA)

Thompson, Simon M.& Wilson, Daniel G. G.& Patel, Nimesh& Bradley, Neil W.. A novel method for intraoperative reduction of the mobile meniscal bearing in the oxford unicompartmental knee replacement. Journal of Orthopaedics and Trauma. 2015. Vol. 5, no. 2015, pp.1-2.
https://search.emarefa.net/detail/BIM-655352

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 2

Record ID

BIM-655352