Preliminary study in in vivo CT dosimetry using optically stimulated luminescence detector (OSLD)‎

Other Title(s)

دراسة تمهيدية لحساب الجرعة الإشعاعية داخل جسم الإنسان الصادرة من جهاز التصوير المقطعي باستخدام مقياس الجرعة الإشعاعية بتقنية الحث الضوئي الوميضي

Joint Authors

Kansarah, Abd al-Rahim Abd al-Rahman
Yusuf, Muhammad

Source

Journal of King Abdulaziz University : Engineering Sciences

Issue

Vol. 26, Issue 1 (30 Jun. 2015), pp.85-94, 10 p.

Publisher

King Abdulaziz University Scientific Publishing Center

Publication Date

2015-06-30

Country of Publication

Saudi Arabia

No. of Pages

10

Main Subjects

Medicine

Abstract EN

Optically stimulated luminescence nanoDot dosimeters (OSLD) have been used to measure single point dose distribution along the superior-inferior position at the surface (skin) and in depths, analogous to organ depths.

A customized acrylic phantom of 46 cm length, 20 cm diameter was fabricated, and used for the experimental measurements using CT (Computed Tomography) beam.

The CT dose profile along the surface and the centre of the phantom, as a function of scan field, were measured.

The measured dose due to the primary radiation was quantified and compared with the theoretical dose profile using conventional 100 mm pencil CT ionization chamber.

The OSLD responses at the center axial and the surface were found to be similar with the dose profile from CT ionization chamber.

In this study, the dose at the center axial was found to be higher than the surface dose up to 28.13%.

The dose at the diagonal center was found to be the highest compared to the surface dose up to 61.13%.

The result of this work has revalidated the potential use of OSLD in CT dosimetry as an alternative to TL-dosimetry.

American Psychological Association (APA)

Yusuf, Muhammad& Kansarah, Abd al-Rahim Abd al-Rahman. 2015. Preliminary study in in vivo CT dosimetry using optically stimulated luminescence detector (OSLD). Journal of King Abdulaziz University : Engineering Sciences،Vol. 26, no. 1, pp.85-94.
https://search.emarefa.net/detail/BIM-678306

Modern Language Association (MLA)

Yusuf, Muhammad& Kansarah, Abd al-Rahim Abd al-Rahman. Preliminary study in in vivo CT dosimetry using optically stimulated luminescence detector (OSLD). Journal of King Abdulaziz University : Engineering Sciences Vol. 26, no. 1 (2015), pp.85-94.
https://search.emarefa.net/detail/BIM-678306

American Medical Association (AMA)

Yusuf, Muhammad& Kansarah, Abd al-Rahim Abd al-Rahman. Preliminary study in in vivo CT dosimetry using optically stimulated luminescence detector (OSLD). Journal of King Abdulaziz University : Engineering Sciences. 2015. Vol. 26, no. 1, pp.85-94.
https://search.emarefa.net/detail/BIM-678306

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 91-92

Record ID

BIM-678306