Improving x-ray radiation resistance of concrete used in radio-diagnostic centers

Other Title(s)

تحسين مقاومة الخرسانة المستخدمة في مراكز التشخيص الإشعاعي للأشعة السينية

Dissertant

al-Najjar, Mahmud Adil Mahmud

Thesis advisor

Yasin, Samir Sulayman
Shihadah, Samir Muhammad

Comitee Members

al-Jazzar, Raid Zaki
Arafah, Muhammad Husni

University

Islamic University

Faculty

Faculty of Engineering

Department

Department of Civil Engineering

University Country

Palestine (Gaza Strip)

Degree

Master

Degree Date

2015

English Abstract

The present work aims at improving x-ray radiation resistance of concrete that may be used in radio diagnostic centers.

It is carried out by increasing attenuation properties of normal concrete to satisfy the properties of the shielding material.

Recycled lead from local disposed cars batteries was used in this study.

This waste lead was recycled, treated and added to the constituents of concrete in shot form with maximum size of 1.18 mm at different percentages of lead to cement ratios (0% to 140%) with addition of 20% increments and mixed together to produce homogenous new concrete.

Several tests on fresh and hardened concrete were carried out.

The fresh concrete was tested and performed using slump test to measure its workability.

The testing on hardened concrete was compressive strength at 7 days, 14 days, and 28 days on (100x100x100mm) cubes.

The penetration of x-ray to concrete after 14 days from casting date was done by exposing x-ray source of 100KeV and 120KeV energies using special prisms 200X200 mm of different thicknesses (40 mm, 60 mm, 80 mm, 100 mm).

It is observed from this study that when the lead-to-cement ratio is increased from 0% to 80%, concrete compressive strength and x-ray shielding properties are improved with maximum of 80%.

After that, when the lead to cement ratio is increased from 80% to 140%, the x-ray shielding properties of concrete is increased but its compressive strength is decreased.

This suggests that the optimum percentage of recycled lead shot (RLS) is about 80% of the cement weight.

Also, the results have demonstrated that the density of concrete increases as the percentage of RLS increases, and the workability of concrete decreases while RLS ratio increases.

In addition, linear attenuation coefficient (LAC) was found to decrease and half value layer (HVL) increases as photon energy increases.

The LAC of concrete with 80% of lead, based on x-ray emission at energy 100KeV and 120KeV, was about 1.35 and 1.76 times higher than that of the concrete without lead, respectively.

The HVL of concrete with 80% of lead, based on x-ray emission at energy 100KeV and 120KeV, was about 1.35 and 1.76 less than that of the concrete without lead, respectively.

Main Subjects

Civil Engineering

No. of Pages

106

Table of Contents

Table of contents.

Abstract.

Abstract in Arabic.

Chapter One : Introduction.

Chapter Two : Literature review.

Chapter Three : Constituent materials and experimental program.

Chapter Four : Test results and discussion.

Chapter Five : Conclusions and recommendations.

References.

American Psychological Association (APA)

al-Najjar, Mahmud Adil Mahmud. (2015). Improving x-ray radiation resistance of concrete used in radio-diagnostic centers. (Master's theses Theses and Dissertations Master). Islamic University, Palestine (Gaza Strip)
https://search.emarefa.net/detail/BIM-724149

Modern Language Association (MLA)

al-Najjar, Mahmud Adil Mahmud. Improving x-ray radiation resistance of concrete used in radio-diagnostic centers. (Master's theses Theses and Dissertations Master). Islamic University. (2015).
https://search.emarefa.net/detail/BIM-724149

American Medical Association (AMA)

al-Najjar, Mahmud Adil Mahmud. (2015). Improving x-ray radiation resistance of concrete used in radio-diagnostic centers. (Master's theses Theses and Dissertations Master). Islamic University, Palestine (Gaza Strip)
https://search.emarefa.net/detail/BIM-724149

Language

English

Data Type

Arab Theses

Record ID

BIM-724149