Structural performance of reinforced concrete bubble slabs after exposing to fire flame

Other Title(s)

الأداء الإنشائي للبلاطات الخرسانية المسلحة و المجوفة بعد التعرض الى لهب النار

Author

al-Ghisham, Thair Suud Salman

Source

Journal of Engineering and Development

Issue

Vol. 19, Issue 4 (31 Jul. 2015), pp.1-14, 14 p.

Publisher

al-Mustansyriah University College of Engineering

Publication Date

2015-07-31

Country of Publication

Iraq

No. of Pages

14

Main Subjects

Engineering & Technology Sciences (Multidisciplinary)

Abstract EN

This paper presents the results of experimental program investigating the effect of fire flame (high temperature) on the structural performance of bubble slabs.

The program consisted casting and testing nine specimens.

The dimensions of the specimens were 270 X 500mm in plane and with two different thicknesses; 90 and 140mm.

All specimens were cast with normal concrete of approximately 25 MPa compressive strength.

Seven specimens were burnt using a diesel furnace and two specimens were kept without burning as controls.

The test parameters were; the fire flame temperature (200, 500, and 800 oC), the cooling method is processed gradually by left the slabs in the air or suddenly by using water, the exposure time (1, 1.5, and 2 hours), and thickness of slabs (90 and 140mm).

After cooling, the specimens were simply supported in one direction and tested under a uniform load applied gradually till failure.

The test results showed that, the residual strength of specimens decreased from 71.8% to 21.6% and their central deflection increased with increasing the fire flame-temperature from 200 to 800 o C and exposure time from 1 to 2 hours.

For suddenly cooling specimen the residual flexural strength and central deflection were less than those of same specimen when cooled gradually.

Finally, increasing the thickness of bubble slabs by 56% improved distinctly both the residual strength about 45% and stiffness of specimens

American Psychological Association (APA)

al-Ghisham, Thair Suud Salman. 2015. Structural performance of reinforced concrete bubble slabs after exposing to fire flame. Journal of Engineering and Development،Vol. 19, no. 4, pp.1-14.
https://search.emarefa.net/detail/BIM-829872

Modern Language Association (MLA)

al-Ghisham, Thair Suud Salman. Structural performance of reinforced concrete bubble slabs after exposing to fire flame. Journal of Engineering and Development Vol. 19, no. 4 (Jul. 2015), pp.1-14.
https://search.emarefa.net/detail/BIM-829872

American Medical Association (AMA)

al-Ghisham, Thair Suud Salman. Structural performance of reinforced concrete bubble slabs after exposing to fire flame. Journal of Engineering and Development. 2015. Vol. 19, no. 4, pp.1-14.
https://search.emarefa.net/detail/BIM-829872

Data Type

Journal Articles

Language

English

Notes

Record ID

BIM-829872