Assessment of ISNAG fluorimeter (total fluorescence measurements at+90° &-90° using four solar cell on each side for 100mm distance at 2mm path length)‎ with well-known fluorescent molecules via CFIA

Other Title(s)

تقييم مقياس الفلور ISNAG (القياس للفلورة الكليةعلى +09 °و -09°باستخدام أربعة خلايا شمسية على كل جانب لمسافة 100mm و بمسار تشعيع 2mm)‎ مع جزيئات الفلورة المعروفة عن طريق تقنية الحقن الجرياني المستمر

Joint Authors

Turki, Nagam Shakir
Munshid, Haydar Qays

Source

Iraqi Journal of Science

Issue

Vol. 59, Issue 1B (31 Mar. 2018), pp.240-250, 11 p.

Publisher

University of Baghdad College of Science

Publication Date

2018-03-31

Country of Publication

Iraq

No. of Pages

11

Main Subjects

Chemistry

Topics

Abstract EN

Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7- dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis.

While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively.

The results were compared with classical method at variable λex for both fluorescent molecules at 95% confidence level.

The comparison data shows that ISNAG fluorimeter is the choice with excellent extended detection and a wider applicability.

American Psychological Association (APA)

Turki, Nagam Shakir& Munshid, Haydar Qays. 2018. Assessment of ISNAG fluorimeter (total fluorescence measurements at+90° &-90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA. Iraqi Journal of Science،Vol. 59, no. 1B, pp.240-250.
https://search.emarefa.net/detail/BIM-832069

Modern Language Association (MLA)

Turki, Nagam Shakir& Munshid, Haydar Qays. Assessment of ISNAG fluorimeter (total fluorescence measurements at+90° &-90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA. Iraqi Journal of Science Vol. 59, no. 1B (2018), pp.240-250.
https://search.emarefa.net/detail/BIM-832069

American Medical Association (AMA)

Turki, Nagam Shakir& Munshid, Haydar Qays. Assessment of ISNAG fluorimeter (total fluorescence measurements at+90° &-90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA. Iraqi Journal of Science. 2018. Vol. 59, no. 1B, pp.240-250.
https://search.emarefa.net/detail/BIM-832069

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 249-250

Record ID

BIM-832069