Theoretical prediction of optimum chilled water distribution configuration in air conditioning terminal unit

Other Title(s)

التخمين النظري للتوزيع الأمثل للماء المثلج في الوحدات الطرفية في منظومة التكييف المركزية

Joint Authors

Shabib, Ali Riyad
Salih, Ahmad Abd Muhammad

Source

al-Khwarizmi Engineering Journal

Issue

Vol. 14, Issue 2 (30 Jun. 2018), pp.137-146, 10 p.

Publisher

University of Baghdad al-Khwarizmi College of Engineering

Publication Date

2018-06-30

Country of Publication

Iraq

No. of Pages

10

Main Subjects

Mechanical Engineering

Abstract EN

The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit.

In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit.

The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump.

The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate from all terminal units.

The hydraulic and energy equations governing the performance of unit solved with the aid of FORTRAN code with considering the following parameters: total water flow rate, chilled water supply temperature, and variable valve opening.

It was found that the optimum solution of three-way valve case at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 100%, valve 2: 100% and valve 3: 75%) with total heat rate (987.92 Watt) and standard deviation (1.181E-3).

Also, for the two-way valve case the results showed that the optimum condition at 8°C water supply temperature, 0.12 kg/s total water flow rate and valve opening order (valve 1: 75%, valve 2: 75% and valve 3: 50%) with total heat rate and standard deviation (717Watt) and (5.69E-4) respectively.

American Psychological Association (APA)

Salih, Ahmad Abd Muhammad& Shabib, Ali Riyad. 2018. Theoretical prediction of optimum chilled water distribution configuration in air conditioning terminal unit. al-Khwarizmi Engineering Journal،Vol. 14, no. 2, pp.137-146.
https://search.emarefa.net/detail/BIM-838082

Modern Language Association (MLA)

Salih, Ahmad Abd Muhammad& Shabib, Ali Riyad. Theoretical prediction of optimum chilled water distribution configuration in air conditioning terminal unit. al-Khwarizmi Engineering Journal Vol. 14, no. 2 (Jun. 2018), pp.137-146.
https://search.emarefa.net/detail/BIM-838082

American Medical Association (AMA)

Salih, Ahmad Abd Muhammad& Shabib, Ali Riyad. Theoretical prediction of optimum chilled water distribution configuration in air conditioning terminal unit. al-Khwarizmi Engineering Journal. 2018. Vol. 14, no. 2, pp.137-146.
https://search.emarefa.net/detail/BIM-838082

Data Type

Journal Articles

Language

English

Notes

Includes appendix : p. 145

Record ID

BIM-838082