Development of micro-hardness and wear performances of biomedical titanium

Author

Muhammad, Muhsin T.

Source

Kufa Journal of Engineering

Issue

Vol. 9, Issue 2 (30 Apr. 2018), pp.131-138, 8 p.

Publisher

University of Kufa Faculty of Engineering

Publication Date

2018-04-30

Country of Publication

Iraq

No. of Pages

8

Main Subjects

Physics

Abstract EN

In the present work, the influence of thermal oxidation (TO) process on the micro-hardness and wear performances of a pure titanium (Ti) was studied.

The process has been carried out at various values of temperature for determined time followed by furnace cooling to room temperature.

The TO has supported the development of strong surface film on the Ti without spallation.

This surface structure improved the results of micro-hardness and wear compared to untreated samples.

American Psychological Association (APA)

Muhammad, Muhsin T.. 2018. Development of micro-hardness and wear performances of biomedical titanium. Kufa Journal of Engineering،Vol. 9, no. 2, pp.131-138.
https://search.emarefa.net/detail/BIM-840842

Modern Language Association (MLA)

Muhammad, Muhsin T.. Development of micro-hardness and wear performances of biomedical titanium. Kufa Journal of Engineering Vol. 9, no. 2 (Apr. 2018), pp.131-138.
https://search.emarefa.net/detail/BIM-840842

American Medical Association (AMA)

Muhammad, Muhsin T.. Development of micro-hardness and wear performances of biomedical titanium. Kufa Journal of Engineering. 2018. Vol. 9, no. 2, pp.131-138.
https://search.emarefa.net/detail/BIM-840842

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p.136-138

Record ID

BIM-840842