استخدام الأنابيب الحرارية في أنظمة تكييف الهواء كمبادل حراري لاسترجاع الحرارة الضائعة
Other Title(s)
Using heat pipes in air conditioning systems as a heat exchanger to recovery of waste heat
Author
Source
مجلة جامعة دمشق للعلوم الهندسية
Issue
Vol. 31, Issue 3 (31 Dec. 2015), pp.99-107, 9 p.
Publisher
Publication Date
2015-12-31
Country of Publication
Syria
No. of Pages
9
Main Subjects
Abstract EN
The recovery of waste heat contribute to decrease power consumption and increase the effectiveness of heating systems.
So a heat pipe heat exchanger has been studied and constructed for heat recovery.
To use it in many places such as laboratories and hospitals where the air must be changed up to 40 times per hour, air-to-air heat pipe heat exchanger was designed, constructed and tested under low temperature (15-55ºC) operating conditions, using methanol as the working fluid.
The absorbed heat by the evaporator section are very close to the applicable heat transfer rate
American Psychological Association (APA)
مدلل، غسان. 2015. استخدام الأنابيب الحرارية في أنظمة تكييف الهواء كمبادل حراري لاسترجاع الحرارة الضائعة. مجلة جامعة دمشق للعلوم الهندسية،مج. 31، ع. 3، ص ص. 99-107.
https://search.emarefa.net/detail/BIM-873850
Modern Language Association (MLA)
مدلل، غسان. استخدام الأنابيب الحرارية في أنظمة تكييف الهواء كمبادل حراري لاسترجاع الحرارة الضائعة. مجلة جامعة دمشق للعلوم الهندسية مج. 31، ع. 3 (2015)، ص ص. 99-107.
https://search.emarefa.net/detail/BIM-873850
American Medical Association (AMA)
مدلل، غسان. استخدام الأنابيب الحرارية في أنظمة تكييف الهواء كمبادل حراري لاسترجاع الحرارة الضائعة. مجلة جامعة دمشق للعلوم الهندسية. 2015. مج. 31، ع. 3، ص ص. 99-107.
https://search.emarefa.net/detail/BIM-873850
Data Type
Journal Articles
Language
Arabic
Notes
يتضمن مراجع ببليوجرافية : ص. 106
Record ID
BIM-873850