CPRD supplied with native scintillator for radon gas detection

Author

Abd Allah, Ayman Muhammad Abd al-Muti

Source

Arab Journal of Nuclear Sciences and Applications

Issue

Vol. 52, Issue 3 (31 Jul. 2019), pp.90-97, 8 p.

Publisher

The Egyptian Society of Nuclear Science and Applications

Publication Date

2019-07-31

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Physics

Topics

Abstract EN

For neutron detection and radioactive gas sensing, it is greatly beneficial to detect alpha (α) particles and gamma rays.

In the present work, continuous passive radon detector (CPRD) has been constructed with native ZnS; AgCl scintillator.

The detector has been supplied with highly efficient native nano particles scintillator for detection of α particles.

One of the features of this scintillator, the energy resolution is comparable with or even better than commercial ZnS (Ag) scintillator.

This study provides an alternative for the fabrication the native scintillator in the absence of costly scintillator available in the market.

Moreover, results of scintillation characteristics, along with physical properties of the scintillator, are addressed and thoroughly discussed.

For calibration, radon calibration system with dual radon monitor has been constructed in Najran University, Saudi Arabia.

The experimental sensitivity of the passive CPRD cell for radon gas detection was constant with well-known data already published in the literatures.

Radon emission from a natural sample has been measured by the fabricated CPRD cell.

American Psychological Association (APA)

Abd Allah, Ayman Muhammad Abd al-Muti. 2019. CPRD supplied with native scintillator for radon gas detection. Arab Journal of Nuclear Sciences and Applications،Vol. 52, no. 3, pp.90-97.
https://search.emarefa.net/detail/BIM-891740

Modern Language Association (MLA)

Abd Allah, Ayman Muhammad Abd al-Muti. CPRD supplied with native scintillator for radon gas detection. Arab Journal of Nuclear Sciences and Applications Vol. 52, no. 3 (Jul. 2019), pp.90-97.
https://search.emarefa.net/detail/BIM-891740

American Medical Association (AMA)

Abd Allah, Ayman Muhammad Abd al-Muti. CPRD supplied with native scintillator for radon gas detection. Arab Journal of Nuclear Sciences and Applications. 2019. Vol. 52, no. 3, pp.90-97.
https://search.emarefa.net/detail/BIM-891740

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 96-97

Record ID

BIM-891740