Reducing short circuit level in 400kv Iraqi grid system by using FACTS device

Joint Authors

al-Asam, Muhannad al-Shaykh Tarrad
Ali, Inam Ibrahim

Source

Iraqi Journal of Computer, Communications and Control Engineering

Issue

Vol. 19, Issue 2 (30 Apr. 2019), pp.90-99, 10 p.

Publisher

University of Technology

Publication Date

2019-04-30

Country of Publication

Iraq

No. of Pages

10

Main Subjects

Electronic engineering

Abstract EN

Electrical power systems are different in their sizes because of their amount of generation power stations, substations, transmission lines and loads.

therefore, these factors may impact on short circuit levels values.

capacity of power stations and dummy transmission lines in extra high voltage grid (400kv) of the Iraqi electrical power grids cause high short circuit levels values such that exceed both rating of the peak and breaking capacity of switchgear equipment's.

reduction of short-circuit levels by using fast-acting flexible alternating current transmission systems (facts) types devices in power grids maintain the operation of power grids with acceptable value of short circuit levels for their electrical equipment's and preventing cascading event outages which may lead to blackouts.

this paper mainly studies strategies on how to add short circuit current limiter (SCCL) device by determining its number, value and location of connection in power grids by programing with (PSS™E version 30.3 package program).

IEEE 25-bus system is used for testing the adding series sccl at power transmission lines method procedure.

the results of adding series SCCL with power transmission lines give significant reducing short circuit levels for the stations have highest short circuit levels in order to prevent the blackouts of overall power grid.

American Psychological Association (APA)

Ali, Inam Ibrahim& al-Asam, Muhannad al-Shaykh Tarrad. 2019. Reducing short circuit level in 400kv Iraqi grid system by using FACTS device. Iraqi Journal of Computer, Communications and Control Engineering،Vol. 19, no. 2, pp.90-99.
https://search.emarefa.net/detail/BIM-898664

Modern Language Association (MLA)

Ali, Inam Ibrahim& al-Asam, Muhannad al-Shaykh Tarrad. Reducing short circuit level in 400kv Iraqi grid system by using FACTS device. Iraqi Journal of Computer, Communications and Control Engineering Vol. 19, no. 2 (Apr. 2019), pp.90-99.
https://search.emarefa.net/detail/BIM-898664

American Medical Association (AMA)

Ali, Inam Ibrahim& al-Asam, Muhannad al-Shaykh Tarrad. Reducing short circuit level in 400kv Iraqi grid system by using FACTS device. Iraqi Journal of Computer, Communications and Control Engineering. 2019. Vol. 19, no. 2, pp.90-99.
https://search.emarefa.net/detail/BIM-898664

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 99

Record ID