Mid-urethral sling for stress incontinence : does urodynamic pressure reading aff ect post-operative outcome ?

Other Title(s)

تأثير ضغط المثانة في سلس البول الاجهادي و تأثيره على نتائج عمليات شريط المثانة

Joint Authors

al-Abbad, Ali
Abu Ziqa, Malak
Bankhar, Mayy Ahmad
Elterman, Dean S.
Radomski, Sidney
Hassunah, Majdi
Ghazi, Abd Allah

Source

Journal of King Abdulaziz University : Medical Sciences

Issue

Vol. 26, Issue 1 (31 Mar. 2019), pp.11-18, 8 p.

Publisher

King Abdulaziz University Scientific Publishing Center

Publication Date

2019-03-31

Country of Publication

Saudi Arabia

No. of Pages

8

Main Subjects

Medicine

Abstract EN

The aim of our study was to determine the eff ect of preoperative urodynamic reading of Valsalva leak point pressure on the result of mid-urethral sling surgery.

From January 2010 to December 2014, a total of 207 patients underwent mid-urethral sling surgery at the Toronto Western Hospital.

An incontinence questionnaire was sent to 94 patients who accepted to be involved in the study to examine satisfaction post-surgery.

Forty-fi ve patients replied and were included in the analysis.

The patients were divided into three groups according to valsalva leak point pressure (< 60, 60-80 and > 80 cm H2O) determined on urodynamic testing.

Of the forty-fi ve patients who responded to the questionnaire, seven were excluded for only having had stress testing done and two were excluded due to intermittent catheterization.

Thirteen patients had evidence of detrusor overactivity on urodynamic testing.

Simple linear regression analysis was done for the three groups of the Valsalva leak point pressure values and correlation to satisfaction was found -0.263, -0.236, and -0.148, respectively.

In this current study, we could not fi nd a relation between valsalva leak point pressure values and the selfreported satisfaction post-surgical correction.

American Psychological Association (APA)

Ghazi, Abd Allah& al-Abbad, Ali& Abu Ziqa, Malak& Bankhar, Mayy Ahmad& Elterman, Dean S.& Radomski, Sidney…[et al.]. 2019. Mid-urethral sling for stress incontinence : does urodynamic pressure reading aff ect post-operative outcome ?. Journal of King Abdulaziz University : Medical Sciences،Vol. 26, no. 1, pp.11-18.
https://search.emarefa.net/detail/BIM-933935

Modern Language Association (MLA)

Ghazi, Abd Allah…[et al.]. Mid-urethral sling for stress incontinence : does urodynamic pressure reading aff ect post-operative outcome ?. Journal of King Abdulaziz University : Medical Sciences Vol. 26, no. 1 (2019), pp.11-18.
https://search.emarefa.net/detail/BIM-933935

American Medical Association (AMA)

Ghazi, Abd Allah& al-Abbad, Ali& Abu Ziqa, Malak& Bankhar, Mayy Ahmad& Elterman, Dean S.& Radomski, Sidney…[et al.]. Mid-urethral sling for stress incontinence : does urodynamic pressure reading aff ect post-operative outcome ?. Journal of King Abdulaziz University : Medical Sciences. 2019. Vol. 26, no. 1, pp.11-18.
https://search.emarefa.net/detail/BIM-933935

Data Type

Journal Articles

Language

English

Notes

Includes appendices : p. 16-17

Record ID

BIM-933935