Serum vitamin D level, measured by two methods, in a sample of normal subjects in Basrah

Other Title(s)

مستوى فيتامين (د)‎ في مصل الدم، مقاسا بطريقتين، في عينة من الأشخاص الطبيعيين في البصرة

Joint Authors

Yaqub, Huda A.
Jawad, Abd Allah M.
Haddad, Nizar Samir

Source

The Medical Journal of Basrah University

Issue

Vol. 37, Issue 2 (31 Dec. 2019), pp.106-114, 9 p.

Publisher

University of Basrah College of Medicine

Publication Date

2019-12-31

Country of Publication

Iraq

No. of Pages

9

Main Subjects

Medicine

Abstract EN

Background: Low vitamin D levels had been reported to be common in normal subjects worldwide.

Studies in the Middle East had reported extremely low levels of serum vitamin D, despite high exposure to sunlight.

Aim: To estimate vitamin D serum concentration in a sample of apparently healthy subjects from Basrah, by 2 methods (chemiluminescent and fluorescent assays).

Methods: The study was carried out on apparently healthy subjects during the period from September 2018 to February 2019.

Quantitative determination of the total 25-hydroxy vitamin D in serum was made using chemiluminescent microparticle immunoassay and enzyme-linked fluorescent assay.

Other parameters (calcium, phosphorus, alkaline phosphatase, parathyroid hormone, hemoglobin, and erythrocyte sedimentation rate and body mass index) were also measured.

Results: The mean level of vitamin D measured by the two methods, was 11.57±6.63 ng/ml and 13.31±6.52 ng/ml by chemiluminescent and fluorescent assays respectively.

The prevalence of vitamin D deficiency was high, where more than 80% of the 57 subjects had vitamin D level below 20 ng/ml.

If the cut-off point of vitamin D deficiency was taken as 10 ng/ml, around 46% of the subjects were found deficient in both methods.

Although the two methods of vitamin D assay were well correlated with each other, fluorescent assay gave, on average, a significantly higher levels compared with the chemiluminescent method.

Serum parathyroid hormone, showed a negative correlation with vitamin D serum levels.

After excluding children and females, no significant difference was found between adult smokers and non-smokers when vitamin D was measured by both methods.

Conclusion: Vitamin D deficiency is common (> 80%) among normal subjects.

The enzyme-linked fluorescent assay resulted in higher mean level than chemiluminescent assay.

The use of a deficiency cutoff point of 10 ng/ml may be more appropriate.

American Psychological Association (APA)

Yaqub, Huda A.& Haddad, Nizar Samir& Jawad, Abd Allah M.. 2019. Serum vitamin D level, measured by two methods, in a sample of normal subjects in Basrah. The Medical Journal of Basrah University،Vol. 37, no. 2, pp.106-114.
https://search.emarefa.net/detail/BIM-946059

Modern Language Association (MLA)

Yaqub, Huda A.…[et al.]. Serum vitamin D level, measured by two methods, in a sample of normal subjects in Basrah. The Medical Journal of Basrah University Vol. 37, no. 2 (2019), pp.106-114.
https://search.emarefa.net/detail/BIM-946059

American Medical Association (AMA)

Yaqub, Huda A.& Haddad, Nizar Samir& Jawad, Abd Allah M.. Serum vitamin D level, measured by two methods, in a sample of normal subjects in Basrah. The Medical Journal of Basrah University. 2019. Vol. 37, no. 2, pp.106-114.
https://search.emarefa.net/detail/BIM-946059

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 113-114

Record ID