Evaluation of flat shallow cavity solar collector inserted with porous layer

Other Title(s)

تقييم مجمع شمسي مسطح نوع حيز ضحل ذو طبقة مسامية

Parallel Title

تقييم مجمع شمسي مسطح نوع حيز ضحل ذو طبقة مسامية

Joint Authors

Zghair, Fahad Abd Allah
Ammuri, Karimah Ismail

Source

The Iraqi Journal for Mechanical and Materials Engineering

Issue

Vol. 19, Issue 4 (31 Dec. 2019), pp.321-336, 16 p.

Publisher

University of Babylon College of Engineering

Publication Date

2019-12-31

Country of Publication

Iraq

No. of Pages

16

Main Subjects

Mechanical Engineering

Topics

Abstract AR

تم تقييم مجمع شمسي مسطح نوع حيز ضحل ذو طبقة مسامية عمليا و عدديا.

الهد ف من هذا العمل هو تحسين الاداءالحراري لمجمع شمسي مسطح باستخدام تقنيات تحسين الانتقال الحراري.

صنعت الماده المسامية من طبقات متعدده منشبكة الالمنيوم بسمك 25 ملم و ذو مسامية مقدارها 0.

9 و ذو نفاذية بمقدار 84.

87 ووضعت بتماس اسفل السطح الماص.

تم تنصيب المجمع الشمسي في بغداد باتجاه الجنوب و بزاوية ميل 45 لقد تم تصميم و تصنيع ثلاثة انواع من المجمعات.

̊الشمسية وهي مجمع شمسي مسطح نوع حيز ضحل ) النموذج الاول(، مجمع الشمسي مسطح نوع حيز ضحل يحتويجزئيا على الطبقة المسامية ) النموذج الثاني( و مجمع شمسي مسطح نوع حيز ضحل و بثلاثة قنوات متموجة الجوانبويحتوي جزئيا على الطبقة المسامية )النموذج الثالث(.

بينت النتائج ان النموذج الثالث اعطى اعلى فرق بدرجة حرارةالماء بين الخروج و الدخول من والى هذا المجمع الشمسي)زادت على 7.

21 م(.

و زادت درجة حرارة الماء الخارج من ̊المجمع تتجاوز 50 م عند منتصف النهار خلال شهر تشرين الثاني وكانون الاول ̊ 2013.

مدى الكفاءه الحرارية للنموذجالثالث كانت 47.

52 % الى 52.

2 %، و للنموذج الأول كانت تتراوح من 33.

5 % الى 42.

3.

Abstract EN

The evaluation of flat shallow cavity solar collector inserted with porous substrate was investigated experimentally and numerically.

The aim of this work is to improve the thermal performance of flat plate solar collectors using enhanced heat transfer technique.

Porous media were made of multilayer of aluminum mesh to form a porous layer of thickness 25 mm inserted under the orber plate with porosity of 0.

9 and permeability of 84.

87.

The solar collector was installed in Baghdad south facing at a fixed tilt angle (45°).

Three types of solar collector have been designed and constructed namely solar collector made of shallow enclosure (model I), solar collector made of shallow enclosure inserted partially with porous layer (model II) and solar collector with channels of corrugated channels inserted partially with porous layer (model III).

The results of parametric study of model III in case of continuous operating showed that the maximum average water temperature difference of water between collector outlet and inlet exceeds (7.

21°C) and the maximum outlet temperature exceeds (50°C) at solar noon for (November, and December 2013).

The thermal efficiency for collector model III was ranged from 47.

52% to 52.

2%, while that for model I was ranged (33.

5% to 42.

3%) under the same environmental conditions.

American Psychological Association (APA)

Ammuri, Karimah Ismail& Zghair, Fahad Abd Allah. 2019. Evaluation of flat shallow cavity solar collector inserted with porous layer. The Iraqi Journal for Mechanical and Materials Engineering،Vol. 19, no. 4, pp.321-336.
https://search.emarefa.net/detail/BIM-973895

Modern Language Association (MLA)

Ammuri, Karimah Ismail& Zghair, Fahad Abd Allah. Evaluation of flat shallow cavity solar collector inserted with porous layer. The Iraqi Journal for Mechanical and Materials Engineering Vol. 19, no. 4 (Dec. 2019), pp.321-336.
https://search.emarefa.net/detail/BIM-973895

American Medical Association (AMA)

Ammuri, Karimah Ismail& Zghair, Fahad Abd Allah. Evaluation of flat shallow cavity solar collector inserted with porous layer. The Iraqi Journal for Mechanical and Materials Engineering. 2019. Vol. 19, no. 4, pp.321-336.
https://search.emarefa.net/detail/BIM-973895

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 335-336

Record ID