Effect of extenders on the characteristic and fertility of cooled buffalo semen

Other Title(s)

تأثير المخففات على خصائص وخصوبة السائل المنوي المبرد لطلائق الجاموس

Joint Authors

Futuh, al-Sayyid Muhammad
Darwish, Sami Anwar
al-Kon, Ismail Ismail
Faraj, Fadi Samir

Source

Kafr El-Sheikh Veterinary Medical Journal

Issue

Vol. 6, Issue 2 (30 Oct. 2008), pp.254-273, 20 p.

Publisher

Kafr El-Sheikh University Faculty of Veterinary Medicine

Publication Date

2008-10-30

Country of Publication

Egypt

No. of Pages

20

Main Subjects

Medicine

Topics

Abstract AR

أجريت هذه الدراسة لمعرفة تأثير المخففات على خصائص و معدل الخصوبة السائل المنوي المبرد لطلائق الجاموس.

- تم تجميع السائل المنوي مرتين أسبوعيا باستخدام المهبل الصناعي من خمسة طلائق جاموس تتراوح أعمارهم من 5 – 6 سنوات.

- تم التقييم للسائل المنوي بعد التجميع لاختيار القذفات المناسبة للتبريد.

- تم تخفيف السائل المنوي باستخدام ثلاثة مخففات هي الترس، اللبن منزوع الدسم و السترات مع صفار البيض.

- تم تبريد السائل المنوي ببطء إلى درجة 5م و تم تقييم السائل المنوي المبرد يوميا بعد 24، 6، 48، 72، 96 ساعة من التبريد كالآتي : 1- الحركة الفردية للحيامن 2- النسبة المئوية للحيامن الحية 3- نسبة سلامة غشاء البلازما للحيامن 4- نسبة سلامة غشاء الاكروسوم للحيامن 5- حساب معدلات الحيوية - تم حساب معدل الإخصاب بعد التلقيح الإصطناعي باستخدام السائل المنوي المبرد لمدة 96 ساعة - أظهرت الدراسة النتائج الآتية : 1- وجد أن هناك تأثير معنوي لكل من مخففات السائل المنوي و كذلك زمن التخزين على خصائص السائل المنوي المبرد للجاموس و كانت أعلى معدلات لمخفف التريس ثم اللبن منزوع الدسم ثم مخفف السترات.

2- وجد أن هناك تأثير معنوي لكل من مخففات السائل المنوي على معدل الإخصاب و كان أعلى معدل إخصاب لمخفف الترس.

Abstract EN

The present study was conducted to investigate the effect of semen extenders on the characteristics of cooled buffalo semen and to determine the suitable extender which will give higher conception rate.

Semen was collected from five buffalo (5-6 years) bulls twice weekly using artificial vagina.

Freshly collected semen samples were evaluated and ejaculates of at least 70% individual motility and 6x106 sperm /ml were pooled, divided into three parts, diluted with tris egg yolk, citrate egg yolk or skimmed milk extender and cooled slowly to 5oC.

Semen samples were evaluated for individual motility, alive sperm, plasma and acrosomal membranes integrity as well as viability index.

Conception rates of buffalo cows artificially inseminated with cooled buffalo semen were also estimated.

The results of the present study revealed that semen extender and storage time exert a highly significant effects on the characteristics of cooled buffalo semen with the higher values recorded for tris egg yolk diluted samples.

The conception rate of cooled buffalo semen was significantly (P<0.01) higher in tris (70%) diluted samples than skimmed milk (60%) and egg yolk citrate (50%) extended samples.

It was concluded that the tris egg yolk extender is the most satisfactory buffering system to improve the post-cooling semen quality in buffalo and gave the best conception rate.

American Psychological Association (APA)

al-Kon, Ismail Ismail& Futuh, al-Sayyid Muhammad& Darwish, Sami Anwar& Faraj, Fadi Samir. 2008. Effect of extenders on the characteristic and fertility of cooled buffalo semen. Kafr El-Sheikh Veterinary Medical Journal،Vol. 6, no. 2, pp.254-273.
https://search.emarefa.net/detail/BIM-98342

Modern Language Association (MLA)

al-Kon, Ismail Ismail…[et al.]. Effect of extenders on the characteristic and fertility of cooled buffalo semen. Kafr El-Sheikh Veterinary Medical Journal Vol. 6, no. 2 (2008), pp.254-273.
https://search.emarefa.net/detail/BIM-98342

American Medical Association (AMA)

al-Kon, Ismail Ismail& Futuh, al-Sayyid Muhammad& Darwish, Sami Anwar& Faraj, Fadi Samir. Effect of extenders on the characteristic and fertility of cooled buffalo semen. Kafr El-Sheikh Veterinary Medical Journal. 2008. Vol. 6, no. 2, pp.254-273.
https://search.emarefa.net/detail/BIM-98342

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 268-273

Record ID

BIM-98342