Ascorbic Acid Determination in Commercial Fruit Juice Samples by Cyclic Voltammetry

Joint Authors

Danet, Andrei Florin
Kalinowski, Slawomir
Pisoschi, Aurelia Magdalena

Source

Journal of Analytical Methods in Chemistry

Issue

Vol. 2008, Issue 2008 (31 Dec. 2008), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2009-02-15

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Chemistry

Abstract EN

A method was developed for assessing ascorbic acid concentration in commercial fruit juice by cyclic voltammetry.

The anodic oxidation peak for ascorbic acid occurs at about 490 mV on a Pt disc working electrode (versus SCE).

The influence of the potential sweep speed on the peak height was studied.

The obtained calibration graph shows a linear dependence between peak height and ascorbic acid concentration in the domain (0.1–10 mmol⋅L−1).

The equation of the calibration graph was y=6.391x+0.1903 (where y represents the value of intensity measured for the anodic peak height, expressed as μA and x the analyte concentration, as mmol⋅L−1, r2=0.9995, r.s.d.=1.14%, n=10, Cascorbic acid=2 mmol⋅L−1).

The developed method was applied to ascorbic acid assessment in fruit juice.

The ascorbic acid content determined ranged from 0.83 to 1.67 mmol⋅L−1 for orange juice, from 0.58 to 1.93 mmol⋅L−1 for lemon juice, and from 0.46 to 1.84 mmol⋅L−1 for grapefruit juice.

Different ascorbic acid concentrations (from standard solutions) were added to the analysed samples, the degree of recovery being comprised between 94.35% and 104%.

Ascorbic acid determination results obtained by cyclic voltammetry were compared with those obtained by the volumetric method with dichlorophenol indophenol.

The results obtained by the two methods were in good agreement.

American Psychological Association (APA)

Pisoschi, Aurelia Magdalena& Danet, Andrei Florin& Kalinowski, Slawomir. 2009. Ascorbic Acid Determination in Commercial Fruit Juice Samples by Cyclic Voltammetry. Journal of Analytical Methods in Chemistry،Vol. 2008, no. 2008, pp.1-8.
https://search.emarefa.net/detail/BIM-987973

Modern Language Association (MLA)

Pisoschi, Aurelia Magdalena…[et al.]. Ascorbic Acid Determination in Commercial Fruit Juice Samples by Cyclic Voltammetry. Journal of Analytical Methods in Chemistry No. 2008 (2008), pp.1-8.
https://search.emarefa.net/detail/BIM-987973

American Medical Association (AMA)

Pisoschi, Aurelia Magdalena& Danet, Andrei Florin& Kalinowski, Slawomir. Ascorbic Acid Determination in Commercial Fruit Juice Samples by Cyclic Voltammetry. Journal of Analytical Methods in Chemistry. 2009. Vol. 2008, no. 2008, pp.1-8.
https://search.emarefa.net/detail/BIM-987973

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-987973