Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

Joint Authors

Liu, Xiang-Long
Gong, Guang-Cai
Cheng, Heng-Sheng
Ding, Li-Xing

Source

Journal of Applied Mathematics

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-12, 12 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-05-08

Country of Publication

Egypt

No. of Pages

12

Main Subjects

Mathematics

Abstract EN

Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system.

This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit.

Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions.

Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows.

The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation.

Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously.

Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

American Psychological Association (APA)

Liu, Xiang-Long& Gong, Guang-Cai& Cheng, Heng-Sheng& Ding, Li-Xing. 2012. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit. Journal of Applied Mathematics،Vol. 2012, no. 2012, pp.1-12.
https://search.emarefa.net/detail/BIM-993116

Modern Language Association (MLA)

Liu, Xiang-Long…[et al.]. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit. Journal of Applied Mathematics No. 2012 (2012), pp.1-12.
https://search.emarefa.net/detail/BIM-993116