Purpose.
To investigate the effectiveness of respiratory guidance system in 4-dimensional computed tomography (4DCT) based respiratory-gated radiation therapy (RGRT) by comparing respiratory signals and dosimetric analysis of treatment plans.
Methods.
The respiratory amplitude and period of the free, the audio device-guided, and the complex system-guided breathing were evaluated in eleven patients with lung or liver cancers.
The dosimetric parameters were assessed by comparing free breathing CT plan and 4DCT-based 30–70% maximal intensity projection (MIP) plan.
Results.
The use of complex system-guided breathing showed significantly less variation in respiratory amplitude and period compared to the free or audio-guided breathing regarding the root mean square errors (RMSE) of full inspiration (P=0.031), full expiration (P=0.007), and period (P=0.007).
The dosimetric parameters including V5 Gy, V10 Gy, V20 Gy, V30 Gy, V40 Gy, and V50 Gy of normal liver or lung in 4DCT MIP plan were superior over free breathing CT plan.
Conclusions.
The reproducibility and regularity of respiratory amplitude and period were significantly improved with the complex system-guided breathing compared to the free or the audio-guided breathing.
In addition, the treatment plan based on the 4D CT-based MIP images acquired with the complex system guided breathing showed better normal tissue sparing than that on the free breathing CT.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lee, Jung Ae& Kim, Chul Yong& Yang, Dae Sik& Yoon, Won Sup& Park, Young Je& Lee, Suk…[et al.]. 2014. Four-Dimensional Computed Tomography Based Respiratory-Gated Radiotherapy with Respiratory Guidance System: Analysis of Respiratory Signals and Dosimetric Comparison. BioMed Research International،Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-1016216
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lee, Jung Ae…[et al.]. Four-Dimensional Computed Tomography Based Respiratory-Gated Radiotherapy with Respiratory Guidance System: Analysis of Respiratory Signals and Dosimetric Comparison. BioMed Research International No. 2014 (2014), pp.1-10.
https://search.emarefa.net/detail/BIM-1016216
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lee, Jung Ae& Kim, Chul Yong& Yang, Dae Sik& Yoon, Won Sup& Park, Young Je& Lee, Suk…[et al.]. Four-Dimensional Computed Tomography Based Respiratory-Gated Radiotherapy with Respiratory Guidance System: Analysis of Respiratory Signals and Dosimetric Comparison. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-1016216
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1016216
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)