Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure

المؤلفون المشاركون

Sakaue, Yuta
Ueda, Jun
Seki, Masaaki
Tanaka, Takayuki
Togano, Tetsuya
Yoshino, Takaiko
Fukuchi, Takeo

المصدر

Journal of Ophthalmology

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-07-10

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To compare a new digital Goldmann applanation tonometer (dGAT) that measures intraocular pressure (IOP) in 0.1 mmHg increments to a standard Goldmann applanation tonometer (sGAT).

Methods.

This study included 116 eyes of 60 subjects.

A single examiner first measured IOP in triplicate using either sGAT or dGAT, which was randomly chosen.

After a 5-minute interval, the next set of three consecutive IOP was measured using the other GAT.

Results.

The mean IOP measured with sGAT was 16.27 ± 6.68 mmHg and 16.35 ± 6.69 mmHg with dGAT.

Pearson’s correlation coefficient was 0.998 ( P < 0.01 ).

The subjects were divided into three groups based on the mean IOP: IOP < 14 mmHg, 14–20 mmHg, or >20 mmHg.

The Pearson’s correlation coefficient within each group was 0.935, 0.972, and 0.997 ( P < 0.01 ), respectively.

The difference within the three consecutive IOP measurements (maximum–minimum) for dGAT (0.72 ± 0.34 mmHg) was significantly smaller than those with sGAT (0.92 ± 0.42 mmHg, P < 0.01 ).

Even in patients with equal IOP (zero left-right difference) with sGAT ( n = 30 ), dGAT detected IOP differences between the left and right eyes (0.47 ± 0.31 mmHg).

Conclusion.

Compared to sGAT, dGAT measurements are highly reproducible and less variable.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Sakaue, Yuta& Ueda, Jun& Seki, Masaaki& Tanaka, Takayuki& Togano, Tetsuya& Yoshino, Takaiko…[et al.]. 2014. Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure. Journal of Ophthalmology،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-1042524

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Sakaue, Yuta…[et al.]. Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure. Journal of Ophthalmology No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-1042524

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Sakaue, Yuta& Ueda, Jun& Seki, Masaaki& Tanaka, Takayuki& Togano, Tetsuya& Yoshino, Takaiko…[et al.]. Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure. Journal of Ophthalmology. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-1042524

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1042524