الملخص EN
Introduction.
In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool.
Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy.
We wanted to identify which MRI sequence can detect DBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods.
Using an IRB approved protocol 8 advanced PD patients were imaged within MR conditional safety guidelines at low RF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.
The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results and Discussion.
Spin echo and fast spin echo based low SAR sequences provided acceptable image quality with comparable image blooming (enlargement) of stimulator leads.
The mean lead diameters were 2.2 ± 0.1 mm for 2D, 2.1 ± 0.1 mm for 3D, and 4.0 ± 0.2 mm for 3D MPRAGE sequence.
Conclusion.
Low RF power spin echo and fast spin echo based 2D and 3D FSE sequences provide acceptable image quality adjacent to DBS leads.
The smallest artifactual blooming of stimulator leads is present on 3D FSE while the largest signal void appears in the 3D MPRAGE sequence.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Sarkar, Subhendra N.& Sarkar, Pooja R.& Papavassiliou, Efstathios& Rojas, Rafael R.. 2014. Utilizing Fast Spin Echo MRI to Reduce Image Artifacts and Improve ImplantTissue Interface Detection in Refractory Parkinson’s Patients with Deep Brain Stimulators. Parkinson’s Disease،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1047213
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Sarkar, Subhendra N.…[et al.]. Utilizing Fast Spin Echo MRI to Reduce Image Artifacts and Improve ImplantTissue Interface Detection in Refractory Parkinson’s Patients with Deep Brain Stimulators. Parkinson’s Disease No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-1047213
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Sarkar, Subhendra N.& Sarkar, Pooja R.& Papavassiliou, Efstathios& Rojas, Rafael R.. Utilizing Fast Spin Echo MRI to Reduce Image Artifacts and Improve ImplantTissue Interface Detection in Refractory Parkinson’s Patients with Deep Brain Stimulators. Parkinson’s Disease. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-1047213
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1047213
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر