Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters

المؤلفون المشاركون

Badarudin, A.
Kamangar, Sarfaraz
Kalimuthu, Govindaraju
Anjum Badruddin, Irfan
Salman Ahmed, N. J.
Khan, T. M. Yunus

المصدر

The Scientific World Journal

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-09-01

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري
تكنولوجيا المعلومات وعلم الحاسوب

الملخص EN

The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR).

The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown.

In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium) is considered in steady and transient conditions for 70% (moderate), 80% (intermediate), and 90% (severe) area stenosis (AS).

For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape.

The pressure drop coefficient (CDP) was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend.

From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models.

A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model.

The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kamangar, Sarfaraz& Kalimuthu, Govindaraju& Anjum Badruddin, Irfan& Badarudin, A.& Salman Ahmed, N. J.& Khan, T. M. Yunus. 2014. Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters. The Scientific World Journal،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1049307

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kamangar, Sarfaraz…[et al.]. Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters. The Scientific World Journal No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1049307

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kamangar, Sarfaraz& Kalimuthu, Govindaraju& Anjum Badruddin, Irfan& Badarudin, A.& Salman Ahmed, N. J.& Khan, T. M. Yunus. Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters. The Scientific World Journal. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1049307

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1049307