Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry

المؤلفون المشاركون

Gabler, Carolin
Bieck, Richard
Göhler, Rebecca
Haenle, Maximilian
Meichsner, Jürgen
Testrich, Holger
Nowottnick, Mathias
Frerich, Bernhard
Finke, Birgit
Lindner, Tobias
Bader, Rainer
Zietz, Carmen

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-04-30

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry.

The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data.

Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats.

Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating.

After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D).

In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.).

Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry.

Overall, a high correlation coefficient of 0.70 ( p < 0.002 ) was found between 3D and 2D quantification of BIC.

The μCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Gabler, Carolin& Zietz, Carmen& Bieck, Richard& Göhler, Rebecca& Lindner, Tobias& Haenle, Maximilian…[et al.]. 2015. Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry. BioMed Research International،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1054217

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Gabler, Carolin…[et al.]. Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry. BioMed Research International No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1054217

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Gabler, Carolin& Zietz, Carmen& Bieck, Richard& Göhler, Rebecca& Lindner, Tobias& Haenle, Maximilian…[et al.]. Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1054217

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1054217