Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial

المؤلفون المشاركون

Fujiwara, Shunsuke
Komasawa, Nobuyasu
Matsunami, Sayuri
Okada, Daisuke
Minami, Toshiaki

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-06-16

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Background.

Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation.

We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin.

Methods.

Twenty-four anesthesiologists with more than two years of experience performed tracheal intubation on an infant manikin using the AWS and GS, with or without chest compressions.

Results.

In GS trials, none of the participants failed without compressions, while three failed with compressions.

In AWS trials, all participants succeeded regardless of chest compressions.

Intubation time was significantly longer with chest compressions with the GS (P<0.05), but not with the AWS.

Difficulty of operation on a visual analog scale (VAS) for laryngoscopy did not increase significantly with chest compressions with either the GS or the AWS, while the VAS for tube passage through the glottis increased with compressions with the GS, but not with the AWS.

Conclusion.

We conclude that in infant simulations managed by anesthesiologists, the AWS performed better than the GS for endotracheal intubation with chest compressions.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Fujiwara, Shunsuke& Komasawa, Nobuyasu& Matsunami, Sayuri& Okada, Daisuke& Minami, Toshiaki. 2015. Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial. BioMed Research International،Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1054562

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Fujiwara, Shunsuke…[et al.]. Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial. BioMed Research International No. 2015 (2015), pp.1-5.
https://search.emarefa.net/detail/BIM-1054562

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Fujiwara, Shunsuke& Komasawa, Nobuyasu& Matsunami, Sayuri& Okada, Daisuke& Minami, Toshiaki. Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1054562

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1054562