Fully Automated Quantification of the Striatal Uptake Ratio of [99mTc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson’s Disease and the Temporal Regression of Striatal Tracer Uptake

المؤلفون المشاركون

Chiu, Shao-Chieh
Lu, Chin-Song
Weng, Yi-Hsin
Yen, Tzu-Chen
Fang, Yu-Hua Dean

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-08-20

دولة النشر

مصر

عدد الصفحات

11

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

We aimed at improving the existing methods for the fully automatic quantification of striatal uptake of [Tc99m]-TRODAT with SPECT imaging.

Procedures.

A normal [Tc99m]-TRODAT template was first formed based on 28 healthy controls.

Images from PD patients (n=365) and nPD subjects (28 healthy controls and 33 essential tremor patients) were spatially normalized to the normal template.

We performed an inverse transform on the predefined striatal and reference volumes of interest (VOIs) and applied the transformed VOIs to the original image data to calculate the striatal-to-reference ratio (SRR).

The diagnostic performance of the SRR was determined through receiver operating characteristic (ROC) analysis.

Results.

The SRR measured with our new and automatic method demonstrated excellent diagnostic performance with 92% sensitivity, 90% specificity, 92% accuracy, and an area under the curve (AUC) of 0.94.

For the evaluation of the mean SRR and the clinical duration, a quadratic function fit the data with R2=0.84.

Conclusions.

We developed and validated a fully automatic method for the quantification of the SRR in a large study sample.

This method has an excellent diagnostic performance and exhibits a strong correlation between the mean SRR and the clinical duration in PD patients.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Fang, Yu-Hua Dean& Chiu, Shao-Chieh& Lu, Chin-Song& Yen, Tzu-Chen& Weng, Yi-Hsin. 2015. Fully Automated Quantification of the Striatal Uptake Ratio of [99mTc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson’s Disease and the Temporal Regression of Striatal Tracer Uptake. BioMed Research International،Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1055569

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Fang, Yu-Hua Dean…[et al.]. Fully Automated Quantification of the Striatal Uptake Ratio of [99mTc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson’s Disease and the Temporal Regression of Striatal Tracer Uptake. BioMed Research International No. 2015 (2015), pp.1-11.
https://search.emarefa.net/detail/BIM-1055569

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Fang, Yu-Hua Dean& Chiu, Shao-Chieh& Lu, Chin-Song& Yen, Tzu-Chen& Weng, Yi-Hsin. Fully Automated Quantification of the Striatal Uptake Ratio of [99mTc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson’s Disease and the Temporal Regression of Striatal Tracer Uptake. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1055569

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1055569