Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability

المؤلفون المشاركون

Chye, Joachim Loo Say
Mundargi, Raghavendra
Venkataraman, Divya
Kumar, Saranya
Mogal, Vishal
Ortiz, Raphael
Venkatraman, Subbu
Steele, Terry

المصدر

BioMed Research International

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-11-01

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

The aim of the present work is to design and construct an ex vivo bioreactor system to assess the real time viability of vascular tissue.

Porcine carotid artery as a model tissue was used in the ex vivo bioreactor setup to monitor its viability under physiological conditions such as oxygen, pressure, temperature, and flow.

The real time tissue viability was evaluated by monitoring tissue metabolism through a fluorescent indicator “resorufin.” Our ex vivo bioreactor allows real time monitoring of tissue responses along with physiological conditions.

These ex vivo parameters were vital in determining the tissue viability in sensor-enabled bioreactor and our initial investigations suggest that, porcine tissue viability is considerably affected by high shear forces and low oxygen levels.

Histological evaluations with hematoxylin and eosin and Masson’s trichrome staining show intact endothelium with fresh porcine tissue whereas tissues after incubation in ex vivo bioreactor studies indicate denuded endothelium supporting the viability results from real time measurements.

Hence, this novel viability sensor-enabled ex vivo bioreactor acts as model to mimic in vivo system and record vascular responses to biopharmaceutical molecules and biomedical devices.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Mundargi, Raghavendra& Venkataraman, Divya& Kumar, Saranya& Mogal, Vishal& Ortiz, Raphael& Chye, Joachim Loo Say…[et al.]. 2015. Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability. BioMed Research International،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057375

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Mundargi, Raghavendra…[et al.]. Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability. BioMed Research International No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1057375

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Mundargi, Raghavendra& Venkataraman, Divya& Kumar, Saranya& Mogal, Vishal& Ortiz, Raphael& Chye, Joachim Loo Say…[et al.]. Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057375

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1057375