Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm

المؤلفون المشاركون

Leo, Hwa-Liang
Yeow, Siang Lin

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-05-09

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

الطب البشري

الملخص EN

This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach.

An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG.

The influence of FRSG intervention on the hemodynamic performance is analyzed and compared in terms of flow patterns, wall shear stress (WSS), and pressure distribution in the aneurysm.

The findings showed that aortic neck angulations significantly influence the velocity flow field in nonstented models, with larger angulations shifting the mainstream blood flow towards the center of the aorta.

By introducing FRSG treatment into the aneurysm, erratic flow recirculation pattern in the aneurysm sac diminishes while the average velocity magnitude in the aneurysm sac was reduced in the range of 39% to 53%.

FRSG intervention protects the aneurysm against the impacts of high velocity concentrated flow and decreases wall shear stress by more than 50%.

The simulation results highlighted that FRSG may effectively treat aneurysm with high aortic neck angulations via the mechanism of promoting thrombus formation and subsequently led to the resorption of the aneurysm.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yeow, Siang Lin& Leo, Hwa-Liang. 2016. Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm. Computational and Mathematical Methods in Medicine،Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1100120

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yeow, Siang Lin& Leo, Hwa-Liang. Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm. Computational and Mathematical Methods in Medicine No. 2016 (2016), pp.1-10.
https://search.emarefa.net/detail/BIM-1100120

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yeow, Siang Lin& Leo, Hwa-Liang. Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm. Computational and Mathematical Methods in Medicine. 2016. Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1100120

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1100120