Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe
المؤلفون المشاركون
المصدر
International Journal of Corrosion
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-01-19
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
The size of the damaged area of the coating and its position on the pipeline impacted the cathodic protection potential, and there was a damaged area of the greatest impact value.
When damaged area was 300 mm2, the IR drop was the largest, and this situation could easily lead to inadequate protection; when the parallel spacing between pipeline and interference source was unchanged, the measured value curves of cathodic protection potential presented “U” shaped trend with the increasing stray current interference intensity.
Under certain parallel spacing between pipeline and interference source, high alternating stray current intensity would cause serious negative offsets, so that the overprotection of the pipeline occurred, and make the coating crack; there was a parallel threshold length.
When less than the threshold, the pipe-ground potential increases rapidly with the parallel length increasing.
In order to judge whether a pipeline was interference by AC stray current and the risk of stray current corrosion, we should make a comprehensive analysis of the cathodic protection energizing potential, the switch-off potential, AC pipe-soil potential, IR drops, and so on.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ding, Qingmiao& Fan, Yueming. 2016. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion،Vol. 2016, no. 2016, pp.1-8.
https://search.emarefa.net/detail/BIM-1105492
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ding, Qingmiao& Fan, Yueming. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion No. 2016 (2016), pp.1-8.
https://search.emarefa.net/detail/BIM-1105492
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ding, Qingmiao& Fan, Yueming. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion. 2016. Vol. 2016, no. 2016, pp.1-8.
https://search.emarefa.net/detail/BIM-1105492
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1105492
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر