Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe

Joint Authors

Ding, Qingmiao
Fan, Yueming

Source

International Journal of Corrosion

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-01-19

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Civil Engineering

Abstract EN

The size of the damaged area of the coating and its position on the pipeline impacted the cathodic protection potential, and there was a damaged area of the greatest impact value.

When damaged area was 300 mm2, the IR drop was the largest, and this situation could easily lead to inadequate protection; when the parallel spacing between pipeline and interference source was unchanged, the measured value curves of cathodic protection potential presented “U” shaped trend with the increasing stray current interference intensity.

Under certain parallel spacing between pipeline and interference source, high alternating stray current intensity would cause serious negative offsets, so that the overprotection of the pipeline occurred, and make the coating crack; there was a parallel threshold length.

When less than the threshold, the pipe-ground potential increases rapidly with the parallel length increasing.

In order to judge whether a pipeline was interference by AC stray current and the risk of stray current corrosion, we should make a comprehensive analysis of the cathodic protection energizing potential, the switch-off potential, AC pipe-soil potential, IR drops, and so on.

American Psychological Association (APA)

Ding, Qingmiao& Fan, Yueming. 2016. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion،Vol. 2016, no. 2016, pp.1-8.
https://search.emarefa.net/detail/BIM-1105492

Modern Language Association (MLA)

Ding, Qingmiao& Fan, Yueming. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion No. 2016 (2016), pp.1-8.
https://search.emarefa.net/detail/BIM-1105492

American Medical Association (AMA)

Ding, Qingmiao& Fan, Yueming. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe. International Journal of Corrosion. 2016. Vol. 2016, no. 2016, pp.1-8.
https://search.emarefa.net/detail/BIM-1105492

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1105492