Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters

المؤلفون المشاركون

Akova-Budak, Berna
Kıvanç, Sertaç Argun
Çevik, Sadık Gorkem
Tok-Çevik, Mediha

المصدر

Journal of Ophthalmology

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-10-25

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group.

Methods.

This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects.

The anterior segment parameters and geometric corneal parameters such as corneal volume, central corneal thickness, horizontal and vertical corneal radii, anterior and posterior steep, and flat keratometric values were measured with a Scheimpflug camera.

The biomechanical properties were measured with Ocular Response Analyzer.

Results.

One hundred and twenty-two healthy Caucasian subjects (67 males, 55 females) with a mean age of 45.32 ± 20.23 were enrolled.

Both corneal hysteresis and corneal resistance factor were positively correlated with CCT ( r = 0.529 , p < 0.001 ; r = 0.638 , p < 0.001 ) and CV ( r = 0.635 , p < 0.001 ; r = 0.579 , p < 0.001 ) and negatively correlated with age ( r = - 0.373 , p < 0.001 ; r = - 0.249 , p < 0.001 ).

Both in age-gender and multivariate models, CH and CRF had statistically significant negative association with the posterior steep K value.

Conclusions.

CH and CRF are negatively correlated with posterior steep and average posterior K values.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Çevik, Sadık Gorkem& Kıvanç, Sertaç Argun& Akova-Budak, Berna& Tok-Çevik, Mediha. 2016. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Çevik, Sadık Gorkem…[et al.]. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Çevik, Sadık Gorkem& Kıvanç, Sertaç Argun& Akova-Budak, Berna& Tok-Çevik, Mediha. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1110091