Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters

Joint Authors

Akova-Budak, Berna
Kıvanç, Sertaç Argun
Çevik, Sadık Gorkem
Tok-Çevik, Mediha

Source

Journal of Ophthalmology

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-10-25

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Purpose.

To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group.

Methods.

This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects.

The anterior segment parameters and geometric corneal parameters such as corneal volume, central corneal thickness, horizontal and vertical corneal radii, anterior and posterior steep, and flat keratometric values were measured with a Scheimpflug camera.

The biomechanical properties were measured with Ocular Response Analyzer.

Results.

One hundred and twenty-two healthy Caucasian subjects (67 males, 55 females) with a mean age of 45.32 ± 20.23 were enrolled.

Both corneal hysteresis and corneal resistance factor were positively correlated with CCT ( r = 0.529 , p < 0.001 ; r = 0.638 , p < 0.001 ) and CV ( r = 0.635 , p < 0.001 ; r = 0.579 , p < 0.001 ) and negatively correlated with age ( r = - 0.373 , p < 0.001 ; r = - 0.249 , p < 0.001 ).

Both in age-gender and multivariate models, CH and CRF had statistically significant negative association with the posterior steep K value.

Conclusions.

CH and CRF are negatively correlated with posterior steep and average posterior K values.

American Psychological Association (APA)

Çevik, Sadık Gorkem& Kıvanç, Sertaç Argun& Akova-Budak, Berna& Tok-Çevik, Mediha. 2016. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

Modern Language Association (MLA)

Çevik, Sadık Gorkem…[et al.]. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

American Medical Association (AMA)

Çevik, Sadık Gorkem& Kıvanç, Sertaç Argun& Akova-Budak, Berna& Tok-Çevik, Mediha. Relationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110091

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references