A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
المؤلفون المشاركون
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-10، 10ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-05-17
دولة النشر
مصر
عدد الصفحات
10
التخصصات الرئيسية
الملخص EN
This study aimed to identify cardiotocography patterns that discriminate fetal acidemia newborns by comprehensively evaluating the parameters obtained from Holter monitoring during delivery.
Between June 1, 2015, and August 1, 2016, a prospective observational study of 85 patients was conducted using fetal Holter monitoring at the Beijing Obstetrics and Gynecology Hospital, Capital Medical University, China.
Umbilical cord blood was sampled immediately after delivery and fetal acidemia was defined as umbilical cord arterial blood pH < 7.20.
Fetal electrocardiogram- (FECG-) derived parameters, including basal fetal heart rate (BFHR), short-term variation (STV), large acceleration (LA), deceleration capacity (DC), acceleration capacity (AC), proportion of episodes of high variation (PEHV), and proportion of episodes of low variation (PELV), were compared between 16 fetuses with acidemia and 47 without.
The areas under the curve (AUC) of receiver operating characteristics (ROC) were calculated.
Although all the computerized parameters showed predictive values for acidemia (all AUC > 0.50), STV (AUC = 0.84, P<0.001), DC (AUC = 0.84, P<0.001), AC (AUC = 0.80, P<0.001), and PELV (AUC = 0.71, P=0.012) were more strongly associated with fetal acidemia.
Our institutional experience suggests that FECG-derived parameters from Holter monitoring are beneficial in reducing the incidence of neonatal acidemia.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Tian, Ning& Zhang, Weiyuan. 2018. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International،Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1125840
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Tian, Ning& Zhang, Weiyuan. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International No. 2018 (2018), pp.1-10.
https://search.emarefa.net/detail/BIM-1125840
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Tian, Ning& Zhang, Weiyuan. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1125840
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1125840
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر