A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience

Joint Authors

Tian, Ning
Zhang, Weiyuan

Source

BioMed Research International

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-05-17

Country of Publication

Egypt

No. of Pages

10

Main Subjects

Medicine

Abstract EN

This study aimed to identify cardiotocography patterns that discriminate fetal acidemia newborns by comprehensively evaluating the parameters obtained from Holter monitoring during delivery.

Between June 1, 2015, and August 1, 2016, a prospective observational study of 85 patients was conducted using fetal Holter monitoring at the Beijing Obstetrics and Gynecology Hospital, Capital Medical University, China.

Umbilical cord blood was sampled immediately after delivery and fetal acidemia was defined as umbilical cord arterial blood pH < 7.20.

Fetal electrocardiogram- (FECG-) derived parameters, including basal fetal heart rate (BFHR), short-term variation (STV), large acceleration (LA), deceleration capacity (DC), acceleration capacity (AC), proportion of episodes of high variation (PEHV), and proportion of episodes of low variation (PELV), were compared between 16 fetuses with acidemia and 47 without.

The areas under the curve (AUC) of receiver operating characteristics (ROC) were calculated.

Although all the computerized parameters showed predictive values for acidemia (all AUC > 0.50), STV (AUC = 0.84, P<0.001), DC (AUC = 0.84, P<0.001), AC (AUC = 0.80, P<0.001), and PELV (AUC = 0.71, P=0.012) were more strongly associated with fetal acidemia.

Our institutional experience suggests that FECG-derived parameters from Holter monitoring are beneficial in reducing the incidence of neonatal acidemia.

American Psychological Association (APA)

Tian, Ning& Zhang, Weiyuan. 2018. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International،Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1125840

Modern Language Association (MLA)

Tian, Ning& Zhang, Weiyuan. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International No. 2018 (2018), pp.1-10.
https://search.emarefa.net/detail/BIM-1125840

American Medical Association (AMA)

Tian, Ning& Zhang, Weiyuan. A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1125840

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1125840