A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model
المؤلفون المشاركون
Atanacković, Teodor M.
Krivokapic, Branislav
Blagojevic, Zoran
Selesi, Dora
Bascarevic, Zoran
Stevanovic, Vladan
Pilipović, Stevan
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-13، 13ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-05-23
دولة النشر
مصر
عدد الصفحات
13
التخصصات الرئيسية
الملخص EN
The purpose of this work is to develop a new model estimate of the fatigue life of a hip prosthesis due to aseptic loosening as a multifactorial phenomenon.
The formula developed here is a three-parameter model based on Basquin’s law for fatigue, eccentric compression formula for the compressive stress and torsion in the prosthesis due to the horizontal components of the contact force.
With our model, we can accurately predict the durability of a hip prosthesis due to the following four parameters: body weight, femoral offset, duration, and intensity of daily physical activities of a patient.
The agreement of the prediction with the real life of the prosthesis, observed on 15 patients, is found to be adequate.
Based on the formula derived for a particular implant, there was a high degree of concurrence between the model-predicted and actual values of aseptic loosening (durability) proved by the Mann–Whitney U test.
By virtue of the validated model, it is possible to predict, quantitatively, the influence of various factors on the hip life.
For example, we can conclude that a 10% decrease of a patient’s body mass, with all other conditions being the same, causes 5% increase of the hip fatigue life.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Krivokapic, Branislav& Blagojevic, Zoran& Selesi, Dora& Atanacković, Teodor M.& Pilipović, Stevan& Bascarevic, Zoran…[et al.]. 2018. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International،Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1129628
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Krivokapic, Branislav…[et al.]. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International No. 2018 (2018), pp.1-13.
https://search.emarefa.net/detail/BIM-1129628
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Krivokapic, Branislav& Blagojevic, Zoran& Selesi, Dora& Atanacković, Teodor M.& Pilipović, Stevan& Bascarevic, Zoran…[et al.]. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1129628
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1129628
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر