A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model

Joint Authors

Atanacković, Teodor M.
Krivokapic, Branislav
Blagojevic, Zoran
Selesi, Dora
Bascarevic, Zoran
Stevanovic, Vladan
Pilipović, Stevan

Source

BioMed Research International

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-13, 13 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-05-23

Country of Publication

Egypt

No. of Pages

13

Main Subjects

Medicine

Abstract EN

The purpose of this work is to develop a new model estimate of the fatigue life of a hip prosthesis due to aseptic loosening as a multifactorial phenomenon.

The formula developed here is a three-parameter model based on Basquin’s law for fatigue, eccentric compression formula for the compressive stress and torsion in the prosthesis due to the horizontal components of the contact force.

With our model, we can accurately predict the durability of a hip prosthesis due to the following four parameters: body weight, femoral offset, duration, and intensity of daily physical activities of a patient.

The agreement of the prediction with the real life of the prosthesis, observed on 15 patients, is found to be adequate.

Based on the formula derived for a particular implant, there was a high degree of concurrence between the model-predicted and actual values of aseptic loosening (durability) proved by the Mann–Whitney U test.

By virtue of the validated model, it is possible to predict, quantitatively, the influence of various factors on the hip life.

For example, we can conclude that a 10% decrease of a patient’s body mass, with all other conditions being the same, causes 5% increase of the hip fatigue life.

American Psychological Association (APA)

Krivokapic, Branislav& Blagojevic, Zoran& Selesi, Dora& Atanacković, Teodor M.& Pilipović, Stevan& Bascarevic, Zoran…[et al.]. 2018. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International،Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1129628

Modern Language Association (MLA)

Krivokapic, Branislav…[et al.]. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International No. 2018 (2018), pp.1-13.
https://search.emarefa.net/detail/BIM-1129628

American Medical Association (AMA)

Krivokapic, Branislav& Blagojevic, Zoran& Selesi, Dora& Atanacković, Teodor M.& Pilipović, Stevan& Bascarevic, Zoran…[et al.]. A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using CoffinManson Fatigue Model. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1129628

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID