Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs

المؤلفون المشاركون

Hanken, Henning
Eichhorn, Wolfgang
Semmusch, Jan
Jung, Ole
Schön, Gerhard MSc
Schöllchen, Maximilian
Hahn, Michael
Stein, Jamal M.
Reitmeier, Aline
Precht, Clarissa
Smeets, Ralf
Gröbe, Alexander
Heiland, Max

المصدر

BioMed Research International

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-07-17

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants.

Material and Methods.

Titanium implants were inserted in eight Göttingen minipigs.

60 implants were evaluated histologically in ground section specimen and radiologically in CBCT in regard to thickness of the buccal bone.

With random intercept models, the difference of histologic measurements and CBCT measurements of bone thickness was calculated.

Results.

The mean histological thickness of the buccal bone was 5.09 mm (CI 4.11–6.08 mm).

The four raters measured slightly less bone in CBCT than it was found in histology.

The random effect was not significant (p value 1.000).

Therefore, the Intraclass Correlation Coefficient (ICC) was 98.65% (CI 100.00–96.99%).

Conclusion.

CBCT is an accurate technique to measure even thin bone structures in the vicinity of titanium implants.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Gröbe, Alexander& Semmusch, Jan& Schöllchen, Maximilian& Hanken, Henning& Hahn, Michael& Eichhorn, Wolfgang…[et al.]. 2017. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1136456

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Gröbe, Alexander…[et al.]. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1136456

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Gröbe, Alexander& Semmusch, Jan& Schöllchen, Maximilian& Hanken, Henning& Hahn, Michael& Eichhorn, Wolfgang…[et al.]. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1136456

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1136456