Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs
المؤلفون المشاركون
Hanken, Henning
Eichhorn, Wolfgang
Semmusch, Jan
Jung, Ole
Schön, Gerhard MSc
Schöllchen, Maximilian
Hahn, Michael
Stein, Jamal M.
Reitmeier, Aline
Precht, Clarissa
Smeets, Ralf
Gröbe, Alexander
Heiland, Max
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-07-17
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
Purpose.
The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants.
Material and Methods.
Titanium implants were inserted in eight Göttingen minipigs.
60 implants were evaluated histologically in ground section specimen and radiologically in CBCT in regard to thickness of the buccal bone.
With random intercept models, the difference of histologic measurements and CBCT measurements of bone thickness was calculated.
Results.
The mean histological thickness of the buccal bone was 5.09 mm (CI 4.11–6.08 mm).
The four raters measured slightly less bone in CBCT than it was found in histology.
The random effect was not significant (p value 1.000).
Therefore, the Intraclass Correlation Coefficient (ICC) was 98.65% (CI 100.00–96.99%).
Conclusion.
CBCT is an accurate technique to measure even thin bone structures in the vicinity of titanium implants.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Gröbe, Alexander& Semmusch, Jan& Schöllchen, Maximilian& Hanken, Henning& Hahn, Michael& Eichhorn, Wolfgang…[et al.]. 2017. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1136456
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Gröbe, Alexander…[et al.]. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1136456
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Gröbe, Alexander& Semmusch, Jan& Schöllchen, Maximilian& Hanken, Henning& Hahn, Michael& Eichhorn, Wolfgang…[et al.]. Accuracy of Bone Measurements in the Vicinity of Titanium Implants in CBCT Data Sets: A Comparison of Radiological and Histological Findings in Minipigs. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1136456
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1136456
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)