An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks

المؤلف

Jung, Jae-Kwan

المصدر

BioMed Research International

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-01-29

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

This study assessed the clinical acceptability of sintering metal-fabricated 3-unit fixed dental prostheses (FDPs) based on gap sizes.

Ten specimens were prepared on research models by milling sintering metal blocks or by the lost-wax technique (LWC group).

Gap sizes were assessed at 12 points per abutment (premolar and molar), 24 points per specimen (480 points in a total in 20 specimens).

The measured points were categorized as marginal, axial wall, and occlusal for assessment in a silicone replica.

The silicone replica was cut through the mesiodistal and buccolingual center.

The four sections were magnified at 160x, and the thickness of the light body silicone was measured to determine the gap size, and gap size means were compared.

For the premolar part, the mean (standard deviation) gap size was nonsignificantly (p=0.139) smaller in the SMB group (68.6 ± 35.6 μm) than in the LWC group (69.6 ± 16.9 μm).

The mean molar gap was nonsignificantly smaller (p=0.852) in the LWC (73.9 ± 25.6 μm) than in the SMB (78.1 ± 37.4 μm) group.

The gap sizes were similar between the two groups.

Because the gap sizes were within the previously proposed clinically accepted limit, FDPs prepared by sintered metal block milling are clinically acceptable.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Jung, Jae-Kwan. 2017. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks. BioMed Research International،Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1138743

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Jung, Jae-Kwan. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks. BioMed Research International No. 2017 (2017), pp.1-8.
https://search.emarefa.net/detail/BIM-1138743

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Jung, Jae-Kwan. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1138743

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1138743