الملخص EN

In spite of the hazard due to the radiation exposure, preparation of 90Y- and 177Lu-labelled radiopharmaceuticals is still mainly performed using manual procedures.

In the present study the performance of a commercial automatic synthesizer based on disposable cassettes for the labelling of 177Lu- and 90Y-DOTA-conjugated biomolecules (namely, DOTATOC and PSMA-617) was evaluated and compared to a manual and a semiautomated approach.

The dose exposure of the operators was evaluated as well.

More than 300 clinical preparations of both 90Y- and 177Lu-labelled radiopharmaceuticals have been performed using the three different methods.

The mean radiochemical yields for 90Y-DOTATOC were 96.2±4.9%, 90.3±5.6%, and 82.0±8.4%, while for 177Lu-DOTATOC they were 98.3% ± 0.6, 90.8% ± 8.3, and 83.1±5.7% when manual, semiautomated, and automated approaches were used, respectively.

The mean doses on the whole hands for yttrium-90 preparations were 0.15±0.4 mSv/GBq, 0.04±0.1 mSv/GBq, and 0.11±0.3 mSv/GBq for manual, semiautomated, and automated synthesis, respectively, and for lutetium-177 preparations, they were 0.02±0.008 mSv/GBq, 0.01±0.03 mSv/GBq, and 0.01±0.02 mSv/GBq, respectively.

In conclusion, the automated approach guaranteed reliable and reproducible preparations of pharmaceutical grade therapeutic radiopharmaceuticals in a decent RCY.

The radiation exposure of the operators remained comparable to the manual approach mainly due to the fact that a dedicated shielding was still not available for the system.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Iori, Michele& Capponi, Pier C.& Rubagotti, Sara& Esposizione, Luca Rosario& Seemann, Johanna& Pitzschler, Riccardo…[et al.]. 2017. Labelling of 90Y- and 177Lu-DOTA-Bioconjugates for Targeted Radionuclide Therapy: A Comparison among Manual, Semiautomated, and Fully Automated Synthesis. Contrast Media & Molecular Imaging،Vol. 2017, no. 2017, pp.1-12.
https://search.emarefa.net/detail/BIM-1141852

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Iori, Michele…[et al.]. Labelling of 90Y- and 177Lu-DOTA-Bioconjugates for Targeted Radionuclide Therapy: A Comparison among Manual, Semiautomated, and Fully Automated Synthesis. Contrast Media & Molecular Imaging No. 2017 (2017), pp.1-12.
https://search.emarefa.net/detail/BIM-1141852

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Iori, Michele& Capponi, Pier C.& Rubagotti, Sara& Esposizione, Luca Rosario& Seemann, Johanna& Pitzschler, Riccardo…[et al.]. Labelling of 90Y- and 177Lu-DOTA-Bioconjugates for Targeted Radionuclide Therapy: A Comparison among Manual, Semiautomated, and Fully Automated Synthesis. Contrast Media & Molecular Imaging. 2017. Vol. 2017, no. 2017, pp.1-12.
https://search.emarefa.net/detail/BIM-1141852

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1141852