Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy

المؤلفون المشاركون

Florian, Löcherbach
Grimsehl, P.
Sauer, A.
Wyler, S.
Kwiatkowski, M.

المصدر

Case Reports in Urology

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-3، 3ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-10-30

دولة النشر

مصر

عدد الصفحات

3

التخصصات الرئيسية

الطب البشري

الملخص EN

We would like to present the case of a 64-year-old woman who underwent ureterorenoscopy and suffered an iatrogenic ureteral lesion due to an accidental intubation of the left ureter with a Foley-Catheter during the procedure.

A Double-J-Stent was implanted into the damaged ureter, and 6 weeks later it fully recovered.

To our knowledge there are few similar cases described in the literature with none of those having happened during ureterorenoscopy so far.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Florian, Löcherbach& Grimsehl, P.& Sauer, A.& Wyler, S.& Kwiatkowski, M.. 2018. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology،Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1151563

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Florian, Löcherbach…[et al.]. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology No. 2018 (2018), pp.1-3.
https://search.emarefa.net/detail/BIM-1151563

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Florian, Löcherbach& Grimsehl, P.& Sauer, A.& Wyler, S.& Kwiatkowski, M.. Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy. Case Reports in Urology. 2018. Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1151563

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1151563