Development of a Sensitive Chemiluminescence Immunoassay for the Quantification of Folic Acid in Human Serum

المؤلفون المشاركون

Zhang, Ting
Chen, Xiang
Zhou, Qiyang
Wang, ChunXin
Yu, Zheng
Ahamada, Hadji
Bai, Zhonghu
Huang, Xuan

المصدر

Journal of Analytical Methods in Chemistry

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-05-21

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الكيمياء

الملخص EN

Folic acid (FA) is an important vitamin for human growth, especially for pregnant women.

FA deficiency is associated with megaloblastic anemia, neural tube defects, cardiovascular diseases, irritability, diarrhea, and psychiatric disorders.

Normally, FA molecules bind to folate-binding protein (FBP) in the serum as complex.

Before quantify the FA concentration, a releasing procedure should be conducted.

Alkaline condition and tris(2-carboxyethyl)phosphine (TCEP) are used to release binding FA to freeing state.

In this work, a chemiluminescence immunoassay (CLIA) for human serum FA was established by competition model.

Streptavidin (SA) was labeled to magnetic beads by an 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EDAC/NHS) method.

Activated biotin molecules were labeled to FBP molecules purified from milk.

FA was labeled to horseradish peroxidase (HRP) by EDAC to activate the FA molecules.

The pretreated samples or standards were added into the reaction tube with biotin-FBP and FA-horseradish peroxidase (HRP), FA in the sample compete with FA-HRP for binding to biotin-FBP, the signal is inversely proportional to the FA concentration.

The method established shows good thermostability and performance.

The limitation of detection (LOD) is 0.44 ng/mL.

The intra-assay coefficient of variation (CV) is 3.6%–7.1%, the interassay CV is 4.2%–7.5%, and the recovery rate is 92.1%–103.5%.

Cross reactivity (CR) was remarkably low with aminopterin, folinic acid, and methotrexate.

The method shows good correlation with the FA CLIA product from Beckman Coulter; the equation is y = 0.9618x−0.1434 while the R2 value is 0.9224.

The established method is sensitive, rapid, and accurate which can fully satisfy for the clinical requirement.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Chen, Xiang& Zhou, Qiyang& Zhang, Ting& Wang, ChunXin& Yu, Zheng& Ahamada, Hadji…[et al.]. 2019. Development of a Sensitive Chemiluminescence Immunoassay for the Quantification of Folic Acid in Human Serum. Journal of Analytical Methods in Chemistry،Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1169194

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Chen, Xiang…[et al.]. Development of a Sensitive Chemiluminescence Immunoassay for the Quantification of Folic Acid in Human Serum. Journal of Analytical Methods in Chemistry No. 2019 (2019), pp.1-7.
https://search.emarefa.net/detail/BIM-1169194

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Chen, Xiang& Zhou, Qiyang& Zhang, Ting& Wang, ChunXin& Yu, Zheng& Ahamada, Hadji…[et al.]. Development of a Sensitive Chemiluminescence Immunoassay for the Quantification of Folic Acid in Human Serum. Journal of Analytical Methods in Chemistry. 2019. Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1169194

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1169194