Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor

المؤلفون المشاركون

Li, Xiangjun
Spence, Stephen
Chen, Hua
Chu, Wuli
Gibson, Lee

المصدر

International Journal of Rotating Machinery

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-18، 18ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-01-11

دولة النشر

مصر

عدد الصفحات

18

التخصصات الرئيسية

هندسة ميكانيكية

الملخص EN

To address the situations where the casing treatment needs to be used to stabilize axial compressors through strong recirculation, this paper initiated a CFD study to investigate how the flow could be suitably controlled in the casing treatment to minimize the efficiency penalty and increase the flow range.

A counter-swirl self-recirculation casing treatment was first designed on a low speed axial fan rotor as a baseline case.

Then three different slot positions and the influence of including the noise baffle were numerically studied.

Based on the understanding of their coeffects, the shorter noise baffle was considered and it was found that the highest efficiency was achieved in the case of the upstream slot when the length of baffle was suitably adjusted to balance the incoming flow and recirculation.

The largest flow range was achieved by locating the slot at the most downstream position and using a 50% length baffle since it suitably controlled the recirculating flow and relieved the separation at the low-span region.

An optimization study showed that the optimum length of the baffle for efficiency was always larger than for the flow range.

Both of the two optimum values reduce as the slot moves downstream.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Li, Xiangjun& Spence, Stephen& Chen, Hua& Chu, Wuli& Gibson, Lee. 2017. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery،Vol. 2017, no. 2017, pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Li, Xiangjun…[et al.]. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery No. 2017 (2017), pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Li, Xiangjun& Spence, Stephen& Chen, Hua& Chu, Wuli& Gibson, Lee. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery. 2017. Vol. 2017, no. 2017, pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1169651