Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor

Joint Authors

Li, Xiangjun
Spence, Stephen
Chen, Hua
Chu, Wuli
Gibson, Lee

Source

International Journal of Rotating Machinery

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-18, 18 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-01-11

Country of Publication

Egypt

No. of Pages

18

Main Subjects

Mechanical Engineering

Abstract EN

To address the situations where the casing treatment needs to be used to stabilize axial compressors through strong recirculation, this paper initiated a CFD study to investigate how the flow could be suitably controlled in the casing treatment to minimize the efficiency penalty and increase the flow range.

A counter-swirl self-recirculation casing treatment was first designed on a low speed axial fan rotor as a baseline case.

Then three different slot positions and the influence of including the noise baffle were numerically studied.

Based on the understanding of their coeffects, the shorter noise baffle was considered and it was found that the highest efficiency was achieved in the case of the upstream slot when the length of baffle was suitably adjusted to balance the incoming flow and recirculation.

The largest flow range was achieved by locating the slot at the most downstream position and using a 50% length baffle since it suitably controlled the recirculating flow and relieved the separation at the low-span region.

An optimization study showed that the optimum length of the baffle for efficiency was always larger than for the flow range.

Both of the two optimum values reduce as the slot moves downstream.

American Psychological Association (APA)

Li, Xiangjun& Spence, Stephen& Chen, Hua& Chu, Wuli& Gibson, Lee. 2017. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery،Vol. 2017, no. 2017, pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

Modern Language Association (MLA)

Li, Xiangjun…[et al.]. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery No. 2017 (2017), pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

American Medical Association (AMA)

Li, Xiangjun& Spence, Stephen& Chen, Hua& Chu, Wuli& Gibson, Lee. Flow Control by Slot Position and Noise Baffle in a Self-Recirculation Casing Treatment on an Axial Fan-Rotor. International Journal of Rotating Machinery. 2017. Vol. 2017, no. 2017, pp.1-18.
https://search.emarefa.net/detail/BIM-1169651

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID