Real-Time Chest Compression Quality Measurements by Smartphone Camera
المؤلفون المشاركون
Engan, Kjersti
Meinich-Bache, Øyvind
Birkenes, Tonje Søraas
Myklebust, Helge
المصدر
Journal of Healthcare Engineering
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-10-28
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
Out-of-hospital cardiac arrest (OHCA) is recognized as a global mortality challenge, and digital strategies could contribute to increase the chance of survival.
In this paper, we investigate if cardiopulmonary resuscitation (CPR) quality measurement using smartphone video analysis in real-time is feasible for a range of conditions.
With the use of a web-connected smartphone application which utilizes the smartphone camera, we detect inactivity and chest compressions and measure chest compression rate with real-time feedback to both the caller who performs chest compressions and over the web to the dispatcher who coaches the caller on chest compressions.
The application estimates compression rate with 0.5 s update interval, time to first stable compression rate (TFSCR), active compression time (TC), hands-off time (TWC), average compression rate (ACR), and total number of compressions (NC).
Four experiments were performed to test the accuracy of the calculated chest compression rate under different conditions, and a fifth experiment was done to test the accuracy of the CPR summary parameters TFSCR, TC, TWC, ACR, and NC.
Average compression rate detection error was 2.7 compressions per minute (±5.0 cpm), the calculated chest compression rate was within ±10 cpm in 98% (±5.5) of the time, and the average error of the summary CPR parameters was 4.5% (±3.6).
The results show that real-time chest compression quality measurement by smartphone camera in simulated cardiac arrest is feasible under the conditions tested.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Meinich-Bache, Øyvind& Engan, Kjersti& Birkenes, Tonje Søraas& Myklebust, Helge. 2018. Real-Time Chest Compression Quality Measurements by Smartphone Camera. Journal of Healthcare Engineering،Vol. 2018, no. 2018, pp.1-12.
https://search.emarefa.net/detail/BIM-1187480
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Meinich-Bache, Øyvind…[et al.]. Real-Time Chest Compression Quality Measurements by Smartphone Camera. Journal of Healthcare Engineering No. 2018 (2018), pp.1-12.
https://search.emarefa.net/detail/BIM-1187480
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Meinich-Bache, Øyvind& Engan, Kjersti& Birkenes, Tonje Søraas& Myklebust, Helge. Real-Time Chest Compression Quality Measurements by Smartphone Camera. Journal of Healthcare Engineering. 2018. Vol. 2018, no. 2018, pp.1-12.
https://search.emarefa.net/detail/BIM-1187480
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1187480
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر