Transcatheter Closure of Patent Ductus Arteriosus in Elderly Patients: Initial and One-Year Follow-Up Results—Do We Have the Proper Device?
المؤلفون المشاركون
Bialkowski, Jacek
Sukiennik, Adam
Galeczka, Michal
Szkutnik, Malgorzata
Smerdzinski, Sebastian
Knop, Mateusz
Fiszer, Roland
المصدر
Journal of Interventional Cardiology
العدد
المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2020-04-29
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Objectives.
Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult.
The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients.
Methods and results.
Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56–85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres.
All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed.
Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11).
Follow-up was conducted at an outpatient clinic (28/33 patients).
The procedure was successful in all patients.
There was one embolisation, followed by implantation of a larger device.
No major complications were noted.
A small residual shunt was present in echocardiography in one patient after one year.
NYHA class improved in all but two patients (with multiple comorbidities).
Conclusions.
Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications.
Amplatzer duct occluder type II is an attractive device in such patients.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Galeczka, Michal& Szkutnik, Malgorzata& Bialkowski, Jacek& Smerdzinski, Sebastian& Knop, Mateusz& Sukiennik, Adam…[et al.]. 2020. Transcatheter Closure of Patent Ductus Arteriosus in Elderly Patients: Initial and One-Year Follow-Up Results—Do We Have the Proper Device?. Journal of Interventional Cardiology،Vol. 2020, no. 2020, pp.1-8.
https://search.emarefa.net/detail/BIM-1187788
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Galeczka, Michal…[et al.]. Transcatheter Closure of Patent Ductus Arteriosus in Elderly Patients: Initial and One-Year Follow-Up Results—Do We Have the Proper Device?. Journal of Interventional Cardiology No. 2020 (2020), pp.1-8.
https://search.emarefa.net/detail/BIM-1187788
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Galeczka, Michal& Szkutnik, Malgorzata& Bialkowski, Jacek& Smerdzinski, Sebastian& Knop, Mateusz& Sukiennik, Adam…[et al.]. Transcatheter Closure of Patent Ductus Arteriosus in Elderly Patients: Initial and One-Year Follow-Up Results—Do We Have the Proper Device?. Journal of Interventional Cardiology. 2020. Vol. 2020, no. 2020, pp.1-8.
https://search.emarefa.net/detail/BIM-1187788
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1187788
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)