الملخص EN

The current research results indicate that the insulator’s insulation performance has a very important influence on the back-flashover lightning withstand performance of UHVDC transmission lines, especially for ±800 kV voltage level.

However, it is not clear which factors will influence the insulation performance of the insulator, and the influencing mechanism is also not clear yet.

To figure out this problem, the insulator’s insulation performance under different conditions has been deeply analyzed and considered to reveal the influence mechanism in this paper, such as the surface hydrophobicity, pollution degree, and the string type.

Firstly, the insulator’s model is established using COMSOL software, and the lightning impulse voltage of insulator is calculated and verified with the corresponding experimental data.

Then, the ±800 kV UHVDC transmission lines model is constructed using PSCAD software, and back-flashover lightning withstand level and back-flashover rate are calculated by considering the above lightning impulse voltage as the threshold of flashover.

Finally, the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is deeply analyzed based on different insulators.

The simulation results demonstrate that the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is obviously weakened with the increase of the pollution degree and slightly weakened with the decrease of the surface hydrophobicity.

Considering the same pollution degree, the V-type string insulator has the least influence, while the II-type string insulator has the greatest influences on the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines.

The research results are beneficial for providing theoretical basis for stable operation and reliable power supply of ±800 kV UHVDC transmission lines.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Jiang, Wenbo& Tang, Chunlin& Zhou, Bo. 2020. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering،Vol. 2020, no. 2020, pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Jiang, Wenbo…[et al.]. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering No. 2020 (2020), pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Jiang, Wenbo& Tang, Chunlin& Zhou, Bo. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering. 2020. Vol. 2020, no. 2020, pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1195598