Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines

Joint Authors

Jiang, Wenbo
Tang, Chunlin
Zhou, Bo

Source

Mathematical Problems in Engineering

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-15, 15 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-04-30

Country of Publication

Egypt

No. of Pages

15

Main Subjects

Civil Engineering

Abstract EN

The current research results indicate that the insulator’s insulation performance has a very important influence on the back-flashover lightning withstand performance of UHVDC transmission lines, especially for ±800 kV voltage level.

However, it is not clear which factors will influence the insulation performance of the insulator, and the influencing mechanism is also not clear yet.

To figure out this problem, the insulator’s insulation performance under different conditions has been deeply analyzed and considered to reveal the influence mechanism in this paper, such as the surface hydrophobicity, pollution degree, and the string type.

Firstly, the insulator’s model is established using COMSOL software, and the lightning impulse voltage of insulator is calculated and verified with the corresponding experimental data.

Then, the ±800 kV UHVDC transmission lines model is constructed using PSCAD software, and back-flashover lightning withstand level and back-flashover rate are calculated by considering the above lightning impulse voltage as the threshold of flashover.

Finally, the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is deeply analyzed based on different insulators.

The simulation results demonstrate that the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines is obviously weakened with the increase of the pollution degree and slightly weakened with the decrease of the surface hydrophobicity.

Considering the same pollution degree, the V-type string insulator has the least influence, while the II-type string insulator has the greatest influences on the back-flashover lightning withstand performance of ±800 kV UHVDC transmission lines.

The research results are beneficial for providing theoretical basis for stable operation and reliable power supply of ±800 kV UHVDC transmission lines.

American Psychological Association (APA)

Jiang, Wenbo& Tang, Chunlin& Zhou, Bo. 2020. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering،Vol. 2020, no. 2020, pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

Modern Language Association (MLA)

Jiang, Wenbo…[et al.]. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering No. 2020 (2020), pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

American Medical Association (AMA)

Jiang, Wenbo& Tang, Chunlin& Zhou, Bo. Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines. Mathematical Problems in Engineering. 2020. Vol. 2020, no. 2020, pp.1-15.
https://search.emarefa.net/detail/BIM-1195598

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1195598