Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia
المؤلفون المشاركون
Zhou, Xingtao
Chen, Xun
Zhao, Feng
Miao, Huamao
Wang, Xiaoying
Yan, Zhipeng
Li, Meiyan
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-07-03
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
Purpose.
To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia.
Methods.
Sixty-one eyes of 32 patients went through ICL V4c implantation.
Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively.
Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system.
Results.
At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction.
The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26.
Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line.
The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm3, 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm3, 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008, 0.008, and 0.0003, resp.).
Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11).
Conclusion.
Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia.
Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Yan, Zhipeng& Miao, Huamao& Zhao, Feng& Wang, Xiaoying& Chen, Xun& Li, Meiyan…[et al.]. 2018. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology،Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Yan, Zhipeng…[et al.]. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology No. 2018 (2018), pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Yan, Zhipeng& Miao, Huamao& Zhao, Feng& Wang, Xiaoying& Chen, Xun& Li, Meiyan…[et al.]. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology. 2018. Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1197043
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر