Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia
Joint Authors
Zhou, Xingtao
Chen, Xun
Zhao, Feng
Miao, Huamao
Wang, Xiaoying
Yan, Zhipeng
Li, Meiyan
Source
Issue
Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-9, 9 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2018-07-03
Country of Publication
Egypt
No. of Pages
9
Main Subjects
Abstract EN
Purpose.
To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia.
Methods.
Sixty-one eyes of 32 patients went through ICL V4c implantation.
Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively.
Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system.
Results.
At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction.
The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26.
Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line.
The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm3, 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm3, 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008, 0.008, and 0.0003, resp.).
Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11).
Conclusion.
Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia.
Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up.
American Psychological Association (APA)
Yan, Zhipeng& Miao, Huamao& Zhao, Feng& Wang, Xiaoying& Chen, Xun& Li, Meiyan…[et al.]. 2018. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology،Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
Modern Language Association (MLA)
Yan, Zhipeng…[et al.]. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology No. 2018 (2018), pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
American Medical Association (AMA)
Yan, Zhipeng& Miao, Huamao& Zhao, Feng& Wang, Xiaoying& Chen, Xun& Li, Meiyan…[et al.]. Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia. Journal of Ophthalmology. 2018. Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1197043
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID