Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial
المؤلفون المشاركون
Fayiz, Sayyid Hamid Rida
Rahimzadeh, Poupak
Pournajafian, Ali Rida
Ghodraty, Muhammad Rida
Goodarzynejad, Hamidreza
Dogmehchi, Enseyeh
المصدر
Iranian Red Crescent Medical Journal
العدد
المجلد 16، العدد 4 (30 إبريل/نيسان 2014)، ص ص. 1-8، 8ص.
الناشر
تاريخ النشر
2014-04-30
دولة النشر
الإمارات العربية المتحدة
عدد الصفحات
8
التخصصات الرئيسية
الموضوعات
الملخص EN
Background : To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope.
Objectives : The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries.
Patients and Methods : Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms.
All patients received a standardized protocol of general anesthesia.
Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation.
The time taken to perform endotracheal intubation was also noted in both groups.
Results : Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05).
Blood pressures and HR values changed significantly over time within the groups.
Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P < 0.001).
However, there were no significant differences between the two groups in hemodynamic responses at all time points.
Conclusions : The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Pournajafian, Ali Rida& Ghodraty, Muhammad Rida& Fayiz, Sayyid Hamid Rida& Rahimzadeh, Poupak& Goodarzynejad, Hamidreza& Dogmehchi, Enseyeh. 2014. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal،Vol. 16, no. 4, pp.1-8.
https://search.emarefa.net/detail/BIM-366141
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Pournajafian, Ali Rida…[et al.]. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal Vol. 16, no. 4 (Apr. 2014), pp.1-8.
https://search.emarefa.net/detail/BIM-366141
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Pournajafian, Ali Rida& Ghodraty, Muhammad Rida& Fayiz, Sayyid Hamid Rida& Rahimzadeh, Poupak& Goodarzynejad, Hamidreza& Dogmehchi, Enseyeh. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal. 2014. Vol. 16, no. 4, pp.1-8.
https://search.emarefa.net/detail/BIM-366141
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 8
رقم السجل
BIM-366141
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر