Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial

Joint Authors

Fayiz, Sayyid Hamid Rida
Rahimzadeh, Poupak
Pournajafian, Ali Rida
Ghodraty, Muhammad Rida
Goodarzynejad, Hamidreza
Dogmehchi, Enseyeh

Source

Iranian Red Crescent Medical Journal

Issue

Vol. 16, Issue 4 (30 Apr. 2014), pp.1-8, 8 p.

Publisher

Iranian Hospital

Publication Date

2014-04-30

Country of Publication

United Arab Emirates

No. of Pages

8

Main Subjects

Medicine

Topics

Abstract EN

Background : To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope.

Objectives : The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries.

Patients and Methods : Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms.

All patients received a standardized protocol of general anesthesia.

Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation.

The time taken to perform endotracheal intubation was also noted in both groups.

Results : Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05).

Blood pressures and HR values changed significantly over time within the groups.

Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P < 0.001).

However, there were no significant differences between the two groups in hemodynamic responses at all time points.

Conclusions : The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group.

American Psychological Association (APA)

Pournajafian, Ali Rida& Ghodraty, Muhammad Rida& Fayiz, Sayyid Hamid Rida& Rahimzadeh, Poupak& Goodarzynejad, Hamidreza& Dogmehchi, Enseyeh. 2014. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal،Vol. 16, no. 4, pp.1-8.
https://search.emarefa.net/detail/BIM-366141

Modern Language Association (MLA)

Pournajafian, Ali Rida…[et al.]. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal Vol. 16, no. 4 (Apr. 2014), pp.1-8.
https://search.emarefa.net/detail/BIM-366141

American Medical Association (AMA)

Pournajafian, Ali Rida& Ghodraty, Muhammad Rida& Fayiz, Sayyid Hamid Rida& Rahimzadeh, Poupak& Goodarzynejad, Hamidreza& Dogmehchi, Enseyeh. Comparing glide scope video laryngoscope and macintosh laryngoscope regarding hemodynamic responses during orotracheal intubation : a randomized controlled trial. Iranian Red Crescent Medical Journal. 2014. Vol. 16, no. 4, pp.1-8.
https://search.emarefa.net/detail/BIM-366141

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 8

Record ID

BIM-366141