![](/images/graphics-bg.png)
The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants
المؤلفون المشاركون
Matthews, Felix
Grätz, Klaus W.
Metzler, Philipp
Ort, Rebecca
Luebbers, Heinz-Theo
Zemann, Wolfgang
Kruse, Astrid L.
المصدر
العدد
المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2012-08-05
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Ample data exists about the high precision of three-dimensional (3D) scanning devices and their data acquisition of the facial surface.
However, a question remains regarding which facial landmarks are reliable if identified in 3D images taken under clinical circumstances.
Sources of error to be addressed could be technical, user dependent, or patient respectively anatomy related.
Based on clinical 3D photos taken with the 3dMDface system, the intra observer repeatability of 27 facial landmarks in six cleft lip (CL) infants and one non-CL infant was evaluated based on a total of over 1,100 measurements.
Data acquisition was sometimes challenging but successful in all patients.
The mean error was 0.86 mm, with a range of 0.39 mm (Exocanthion) to 2.21 mm (soft gonion).
Typically, landmarks provided a small mean error but still showed quite a high variance in measurements, for example, exocanthion from 0.04 mm to 0.93 mm.
Vice versa, relatively imprecise landmarks still provide accurate data regarding specific spatial planes.
One must be aware of the fact that the degree of precision is dependent on landmarks and spatial planes in question.
In clinical investigations, the degree of reliability for landmarks evaluated should be taken into account.
Additional reliability can be achieved via multiple measuring.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ort, Rebecca& Metzler, Philipp& Kruse, Astrid L.& Matthews, Felix& Zemann, Wolfgang& Grätz, Klaus W.…[et al.]. 2012. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-448717
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ort, Rebecca…[et al.]. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-448717
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ort, Rebecca& Metzler, Philipp& Kruse, Astrid L.& Matthews, Felix& Zemann, Wolfgang& Grätz, Klaus W.…[et al.]. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-448717
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-448717
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)